LED DL1
LED DL2
red
blue
Discontinuous
Off
flashing
Off
Off
Off
Off
Off
Off
Off
Off
1 flash
1 flash
solid/off/blinking
The Air2-MC200 is supplied with a magnet which is to be secured (by means of two
screws) to the side of the contact, in the position indicated by the two notches.
The Air2-MC200 integrates shock and tilt sensors that allows its use without the
need of the magnet.
The Air2-MC200 is equipped with open and dislodgement tamper protection.
The device uses separate channels for the different types of signalling,, thus
allowing precise identification of the alarm source.
The shock and tilt sensors are not subject to certification of this product.
Table 6: Air2-MC200 technical specifications
Battery
"Low battery" fault voltage
Current draw
Operating environmental
conditions
Dimensions (W x H x D)
Magnet dimensions
Security grade
Environmental class
Table 7: Description of Air2-MC200 parts
A
Battery
B
Signalling LED - red (on rear)
C
Microswitch: open/dislodgement/ENROLL
D
Reed contact
The following table indicates the distance in millimeters of the operating capacity
of the magnet depending on the side in use and the axes illustrated in the figure
(values starting from a nominal distance of 10mm, except for axis y-):
Table 8: Distance between magnet and contact (mm)
Axis
x +/-
y -
z +/-
8
LED DL3
LED DL4
green
yellow
Off
Off
Discontinuou
Off
s flashing
solid/
Off
blinking
Continuous
Off
flashing
Continuous
Continuous
flashing
flashing
1 flash
1 flash
Air2-MC200 magnetic contact
type
estimated life
during standby
maximum
temperature
relative humidity
Weight
Colours
(Figure 3 - Air2-MC200, page 114)
Contact long side
Withdrawn
18
18
22
Table 5: LED Signals
PRG LED
red
Off
Off
Off
Off
Off
Off
solid
Lithium CR2 3V
4 years
Less than 2.4V
10μA
30mA
from -10 to +40°C
93% without condensation
35 x 58 x 23mm
30g
13 x 40 x 14mm
White, Brown
2
II
E
Mounting screw hole
F
Tamper screw hole
G
Securing screws
H
Magnet position notches
Near
14
14
18
Signal
Wireless data reception
Programming phase in progress (from 1 to 5, for
SmartLiving only)
Data of the programming phase in progress (for
SmartLiving only)
Enrollment of wireless device in progress
(requested at the control panel)
Erroneous programming
(for example, two devices on the same terminal)
Reset factory default settings
Address Programming (phase 6)
2-2
Note
MAGNET
DETECTION RANGE
Description of products
Wireless accessories
EN 50131-1
EN 50131-5-3
EN 50131-2-6
EN 50130-4
EN 50130-5
CEB T031