Installation and programming manual
Signalling of shock waves is achieved through a tri-axial vibration detector. The
vibration sensibility can be set either from a keypad or via the SmartLeague
software application.
Signalling of tilting (angle change) is achieved through tri-axial tilt sensing. The tilt-
variation value (angle) can be set in relation to the standby position, which is saved
to the memory during the reset-after -alarm phase.
If both shock and tilt sensing are activated, alarm signalling will occur as soon as
one of the two conditions exceeds it respective alarm threshold.
Ferromagnetic materials which are located in the vicinity of the mounting position
can influence the magnetic field and can result in the reduced operating capacity
of the device.
The Air2-MC300 magnetic contact has two screw-in positions for placement
optimization of the device magnet, 90° one from the other.
The Air2-MC300 also provides two terminals which can be configured individually
as input or open-collector output. Configuring the terminals as inputs allows
management of standard zone balancing (NO, NC, single balancing, double
balancing) and also direct interfacing with rollerblind and inertial sensors.
Alarms deriving from magnetic contacts and distinctly from the two terminals are
signalled separately on the control panel.
The device is protected against dislodgement and open-cover tamper.
Table 9: Air2-MC300 technical specifications
Battery
"Low battery" fault voltage
Current draw
Open-collector output
Operating environmental
conditions
Dimensions (W x H x D)
Weight
Magnet dimensions
Colours
Security grade
Environmental class
Table 10: Description of Air2-MC300 parts
A
Battery
B
Antenna
Signalling LED - red
C
ENROLL button
D
Tamper protection
E
GND terminal
F
Terminal T1
G
Terminal T2
The following table indicates the distance in millimeters of the operating capacity
of the magnet depending on the side in use and the axes illustrated in the figure
(values starting from a nominal distance of 0mm, except for axis y-):
Table 11: Distance between magnet and contact (mm)
Axis
Near
x +/-
7
y -
17
z +/-
29
Description of products
Air2-MC300 magnetic contact
type
estimated life
during standby
maximum
temperature
relative humidity
(Figure 2 - Air2-MC300, page 113)
H
I
J
K
L
M
N
O
Contact long side
Withdrawn
10
19
32
Alkaline LR6 AA 1.5V
4 years
Less than 1.15V
30μA
45mA
Max 50mA
from -10 to +40°C
93% without condensation
26 x 108 x 26.5mm
50g
26 x 14.3 x 26.5mm
White, Brown
2
II
Reed contact: short side
Reed contact: long side
Mounting screw hole
Tamper screw hole
Enclosure screw hole
Cable entry
Magnet - short side
Magnet - long side
Contact short side
Near
Withdrawn
7
10
18
20
33
35
SHOCK DETECTION
TILT DETECTION
ATTENTION!
2-3
EN 50131-1
EN 50131-5-3
EN 50131-2-6
EN 50130-4
EN 50130-5
CEB T031