HOW TO REPLACE A SPARE GASKET
Regularly check the status of the green gasket located in the monoblock socket (A6). If necessa-
ry, replace it with the appropriate spare part (P) as below.
Fig. F
Perform the same check on the connection black gasket of the extension tubes (B and B1) and the
handle (A2). If necessary change as below.
Fig. G
- Remove the broken / damaged green gasket.
- Insert the new one on the steam nozzle and push until it is seated.
See (fig. F)
- Lubricate the gasket with some oil.
- Remove the broken/ damaged black gasket.
- Insert the new one on the steam nozzle and push until it is seated.
See (fig. G)
- Lubricate the gasket with some oil.
29
(P)