Franklin Electric Little Giant TE-5.5-MDQ-SC Manual De Instrucciones

Franklin Electric Little Giant TE-5.5-MDQ-SC Manual De Instrucciones

Publicidad

Enlaces rápidos

Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your Little Giant pump. Retain these
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. Little Giant pumps are carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your pump carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!
DESCRIPTION
The TE-5.5-MDQ-SC is a magnetic drive aquarium pump designed
to move water through an aquarium filtration system. The pump
is designed to be installed external to the aquarium and filtration
system, and is usually mounted below the aquarium in the cabinet
that houses the filtration system (Fig. 1).
The pump's motor is thermally protected. The pump head parts
are made of glass-filled polypropylene. The spindle shaft and
thrust washers are ceramic. The impeller-driven magnet is coated
ceramagnet A (barium ferrite) type ceramic with a carbon bushing.
The O-ring seals are Viton®.
The pump is supplied completely preassembled and pretested
from the factory. The power cord is not included.
SAFETY GUIDELINES
DANGER: To avoid possible electric shock, take special care
when using aquarium equipment.
INTERNAL OVERFLOW AREA
SECTEUR INTERNE DE
SURPLUS
ÁREA INTERNA DE
CAPACIDAD EXCESIVA
BIO
BIO
BIO
SUMP
PUISARD
SUMIDERO
MAGNETIC DRIVE
AQUARIUM PUMP
MODEL
TE-5.5-MDQ-SC
CAREFULLY
HAZARDS.
PROTECT
TO
COMPLY
WITH
AQUARIUM
AQUARIUM
ACUARIO
DRIP LOOP
ANNEAU DE SECURITE
LAZO DE GOTEO
PUMP
POMPE
BOMBA
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not use in explosive
atmospheres. Pump should be used with liquids compatible with
pump component materials.
The motor base of this pump could reach 140° F. When installing
the pump, be certain that the mounting surface can withstand this
temperature; otherwise, use a protective insulation between the
surface and the base.
Do not handle pump with wet hands or when standing on a wet or
damp surface, or in water.
In any installation where property damage and/or personal injury
might result from an inoperative or leaking pump due to power
outages, discharge line blockage, or any other reason, use a
backup system(s) and/or alarm.
Support the pump and piping when assembling and when
installed. Failure to do so can cause piping to break, pump to fail,
motor bearing failures, etc.
During normal pump operation, the motor case could reach 150° F;
however, the motor is thermally protected to prevent excessive heat
from damaging the unit.
BEFORE
If the pump falls into the water, DO NOT reach for it! Disconnect
it from power, then retrieve it. If electrical components of the
pump get wet, remove power from the pump immediately (non-
submersible equipment only).
Carefully examine the appliance after installation. Do not apply
THESE
power if there is water on parts not intended to be wet.
Do not operate the pump if it is malfunctioning or if it is dropped
or damaged.
Closely supervise any children near the pump when it is in use.
Unplug the pump from the outlet when not in use, before removing
or installing parts, and before cleaning.
Do not use the pump for anything other than its intended use.
Do not install or store the pump where it will be exposed to
the weather or to temperatures below freezing. This can cause
cracking or distortion that can destroy the pump.
If the pump is mounted on a tank, ensure that it is securely
installed before operating it.
Read and observe all notices on the pump.
Do not attempt repairs yourself. Return the pump to Little Giant or
an authorized service center.
Refer to the schematic on the motor nameplate for 115V and 230V
wiring connections.
INTERNAL OVERFLOW AREA
SECTEUR INTERNE DE SURPLUS
ÁREA INTERNA DE CAPACIDAD EXCESIVA
ANNEAU DE SECURITE
Figure 1
ELECTRICAL CONNECTIONS
DRIP LOOP
LAZO DE GOTEO
PUMP
POMPE
BOMBA
AQUARIUM
AQUARIUM
ACUARIO
FILTERS
FILTRES
FILTROS
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little Giant TE-5.5-MDQ-SC

  • Página 1 Do not use to pump flammable or explosive fluids such as MAGNETIC DRIVE gasoline, fuel oil, kerosene, etc. Do not use in explosive atmospheres. Pump should be used with liquids compatible with AQUARIUM PUMP Franklin Electric Co., Inc. pump component materials. P. O. Box 12010 MODEL Oklahoma City, OK 73157-2010 The motor base of this pump could reach 140°...
  • Página 2: Directives De Sécurité

    OPERATION INTRODUCTION Cette feuille d’instructions vous fournit les informations nécessaires NOTE: When using the TE-5.5-MDQ-SC for aquarium biological pour entretenir et faire fonctionner votre produit Little Giant. filter applications, refer to the instructions and owners manual Conserver ces directives afin de pouvoir les consulter plus tard. supplied by the filter manufacturer.
  • Página 3: Connexions Électriques

    La base du moteur de la pompe peut atteindre 60 °C (140 °F). Lors bien ventilé où elle ne risque pas d’être mouillée lors d’un de l’installation de la pompe, s’assurer que la surface de montage déversement accidentel. peut résister à cette température; si ce n’est pas le cas, placer un 4.
  • Página 4: Descripción

    DESCRIPCIÓN Lea y cumpla con todos los avisos que se encuentran en la bomba. La TE-5.5-MDQ-SC es una bomba para acuarios de propulsión No intente realizar las reparaciones usted mismo. Devuelva la magnética diseñada para mover agua a través de un sistema de bomba a Little Giant o a cualquier centro de servicio autorizado.
  • Página 5 “ Figure 3 REPLACEMENT PARTS • LISTE DES PIÉCES DE RECHANGE • LISTA DE PARTES Item • Part No. • Quantity • Repere • Nº De Piece • Quantité • Artículo No. de pieza DESCRIPTION • NOMENCLATURE • DESCRIPCIÓN Cantidad 185111 Volute•...
  • Página 6: Garantie Limitée

    LIMITED WARRANTY and country to country. Your Little Giant product is guaranteed to be in perfect condition The National Electric Code (in the USA) and similar codes in other when it leaves our Factory. It is warranted against defective countries require a Ground Fault Circuit Interrupter (GFCI) to be materials and workmanship for a period of 12 months from date of installed in the branch circuit supplying fountain equipment rated purchase by the user.
  • Página 7: Garantia Limitada

    À LA PROPRIÉTÉ OU TOUTE AUTRE PERTE INDIRECTE 4. Se permitió que la bomba opere en seco (envío de fluido OU ACCESSOIRE) RÉSULTANT DE L’UTILISATION OU DE cortado). L’INCAPACITÉ D’UTILISATION DE LA POMPE, ET L’ACHETEUR 5. La bomba empleada para hacer circular cualquier otra sustancia CONVIENT QU’IL NE DISPOSE D’AUCUN AUTRE RECOURS.
  • Página 8 Para la ayuda técnica, por favor póngase en contacto ..1.888.956.0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 994101 - 04/2008 ©2008 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Tabla de contenido