Troubleshooting And Repair - T-Fal RAPID PRO Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING AND REPAIR

Problem
Possible reasons
Unable to open because
of pressure in the inner
pot.
Pressure in the pot is
Unable to open lid.
fully released but the
float valve is stuck
because it is too dirty,
and therefore unable to
move down.
Sealing gasket is not
properly installed.
The float valve is stuck
because it is too dirty,
Unable to close lid.
and therefore unable to
move down.
Direction at which lid
was closed is incorrect.
Faulty pressure control
Intense release
resulted in release of
of pressure from
pressure.
pressure limit
Pressure limit valve did
valve.
not fall into place.
Rice: water ratio is
incorrect.
Food is uncooked
No electricity from the
power grid.
E0 displayed on
Lid temperature sensor
digital screen.
is faulty.
E1 displayed on
The bottom sensor open
digital screen.
circuit or short circuit.
E2 displayed on
lid is not locked
digital screen.
E5 displayed on
Abnormal low pressure.
digital screen.
Steam leaking
The sealing gasket was
from lid.
not properly installed.
Solutions
a.Wait for the pressure in the pot to be
completely released automatically.
b. Press and hold the pressure release button.
a. Be sure the pressure is totally released by
complete cool down 2 hours minimum (not
under water).
b. Please use a stick to poke the float valve,
to make it fall down. Be careful, keep your
face away from the lid and the handle.
c. For next use, please clean and wipe the
float valve.
Install the sealing gasket properly.
a. Please use a stick to poke the float valve,
to make it fall down.
b. For next use, please clean and wipe the
float valve (see page 19, cleaning steps of
the float valve).
Remove the lid in the correct direction
according to the instruction manual.
Send to repair and maintenance
department.
Gentling press the pressure limit valve to
make it fall into place.
Use the required rice: water ratio
Be sure the releasing valve is not dirty and
create leakage during cooking.
Check the home electric circuit.
Send to repair and maintenance
department.
Send to repair and maintenance
department
Check if the program selected requires the
lid totally closed .
If yes, completely lock the lid.
If no, send to repair and maintenance
department.
Check that gasket is properly installed and
cleaned.Check that pressure limit valve falls
down into place and is cleaned.Check that
lid fixing nut is well tightened.
Remove the gasket, clean it and reinstall the
sealing gasket properly, in correct position (see
page 19, cleaning steps of the lid gasket).
EN
FR
ES
19

Publicidad

Tabla de contenido
loading

Tabla de contenido