Descargar Imprimir esta página

Master MH-40-GFA Manual De Operacións página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Connect the heater to a three prong (grounded)
power source. You must use a three prong
(grounded) extension cord that is at least 6 feet
long is a minimum of 14 AWG rating.
2. Connect heater to a proper LP cylinder.
3. Turn gas valve CLOCKWISE to off position.
4.
Smell for gas, if you do not smell gas, go to
step 5.
5. Push in and turn gas control knob
COUNTERCLOCKWISE to 1 position. This
will light the burner. If needed, keep pressing
control knob until the burner lights and keep
pressing and turning from "O" (OFF) to 1 on
Piezo electric spark models
(1 on Model 40-GFA).
(See Figure 5)
6. Keep the valve knob depressed for at least
30 seconds after lighting the burner. After 30
seconds, release the valve knob.
7. If the burner does not stay lit, repeat the
lighting procedures.
8. When burner stays lit, turn gas valve knob
COUNTERCLOCKWISE to desired setting
(All models except 40-GFA).
Figure 5
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
40-GFA
Valve Knob
CONNECTED TO A FUEL SOURCE
To Shut Off the Heater:
1. Turn gas valve knob CLOCKWISE to
"O" (OFF) position. (See Figure 5)
2. Turn gas supply OFF by turning the LP
cylinder valve CLOCKWISE to close.
3. Disconnect the power cord.
Test fire your construction heater following the
lighting instructions applicable to the gas control
system employed.
Leak test all gas connections with 50/50 soap
and water solution prior to start-up. Soap bubbles
indicate a gas leak. DO NOT use a match or
flame to test for gas leaks.
Ignition
OFF
60V-GFA-A / 125V-GFA-A / 150V-GFA-A
Propane Forced Air Heater User's Manual
7
Valve Knob
Ignition
OFF

Publicidad

loading

Este manual también es adecuado para:

Mh-60v-gfa-aMh-125v-gfa-aMh-150v-gfa-a