e. The appliance must always be activated paying attention that there are no
obstacles for air suction and output.
f. The appliance must not be used in laundry rooms.
g. Only install the appliance in dry rooms.
h. The appliance must not be started in the presence of dangerous materials, va-
pours or liquids.
i. Clean the air filters at least once a week.
2.3 - ELECTRICAL CONNECTION
The appliance is fitted with a power cable with plug.
Before connecting the appliance, make sure that:
• The voltage and power frequency values match those specified on
the appliance plate data.
• The power supply line is equipped with an efficient ground connection
and that it is correctly dimensioned for the maximum absorption of
the appliance.
• The appliance's power network must be equipped with a suitable omnipolar disconnection device
compliant with national installation regulations.
• The appliance is powered solely through a socket compatible with
the plug provided.
CAUTION
Any replacement of the power cable must be carried out solely by Olimpia
Splendid technical support or by similarly qualified personnel.
3 - USE OF THE APPLIANCE
Before starting the appliance, kindly open the air outlet.
DO NOT insert anything (fingers, hands, objects, etc.) in the air outlet in order
to avoid damaging the appliance.
Cuts or wounds hazard !
a. Appliance start/switch off
Press this key
Press it again to stop the appliance operation. The appliance switches to STANDBY mode; the compressor,
the fan motor and the display are switched off.
b. Humidity level setting
In "RUN" mode, press UP or DOWN to select the desired level of humidity in the room.
The settable value must be included between 30% and 90 % with 5% intervals.
After a certain period of operation, when the percentage of humidity in the room is lower than the set value, the com-
pressor stops temporarily; the led "Compressor status" blinks in green.
When the percentage level of humidity in the room is equal or higher than the minimum set value, after three minutes
(compressor protection time), the compressor restarts; the led "Compressor status" switches steady on in green.
If a humidity value lower than 30% is set by pressing the DOWN key, the display shows "Co". In this condition, the
appliance works continuously independently from the level of humidity in the room. Periodically, when the appliance
is working (RUN mode), dehumidification can be temporarily interrupted in order to defrost the heat exchanger; the
led "Defrosting" switches on in green.
EN - 19
once to start the appliance in "RUN" mode.