Technical Data; List Of Cables Needed; Preliminary Checks - Key Automation CT-724S Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
- Power supply protected against short circuits within the unit, on
motor and connected accessories.
- Power adjustment with chopping of the current.
- Detection of obstacles by monitoring the encoder from the motor.
- Automatic learning of the working time.
- Disabling of safety inputs via dip switches: no need to bridge the

TECHnICAL DATA

External transformer
Maximum power output
Auxiliary power
Operating temperature
Motor
Fuses

2.4 list of cables needed

Typical installation cables required for connection of various devices
are shown in cables list table.
CAbLES LIST TAbLE
Connection
Power supply line
Motor power supply
Encoder connections (keep separated from the supply)
Flashing light
Transmitter photocells
Receiver photocells
Key selector
Fixed edges
Mobile edges
Antenna with RG58 shielded cable

3 - prElIMINAry ChECKs

before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the operat-
ing limits specified for the automation where the product is installed
- Check the presence and strength of the security mechanical stops
of the gate or door
- Check that the mounting area of the product is not subject to flood-
ing
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
peak may be higher than under normal conditions.
terminals related to the safety not installed, by simply disabling the
function with the dip switch.
- Ability to operate with an optional battery without power supply.
- Low voltage output used for a status indicator light or a 24V flash-
ing light.
- Energy savings function.
Secondary output 27 Vac ±10 %, 50 Hz, 150 VA
300W (24 Vac ±10 %, 50 Hz, 12 A)
Stabilized 24 Vdc (max. 300 mA)
-20 °C + 55 °C
24 Vdc nominal, up to 12 A
F1 10 A mains (delayed), F2 2.5 A Lamps (delayed)
The cables used must be suitable for the installation; for example,
we recommend a H03VV-F type cable for indoor installation and
H07Rn-F for outdoor.
from 1 to 10m
from 10 to 20m
3 x 1.5 mm
3 x 1.5 mm
2
2 x 1.5 mm
2 x 1.5 mm
2
3 x 0.5 mm
3 x 0.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
2
4 x 0.5 mm
4 x 0.5 mm
2
3 x 0.5 mm
3 x 0.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
2
RG58 Shielded cable max 10m
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment
- Check that the gate or door are balanced and stationary if left in
any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a gap
beween contacts enabling full disconnection under the conditions
dictated by the overvoltage category III.
- Ensure that all materials used for the installation comply with cur-
rent regulations
from 20 to 30m
3 x 2.5 mm
2
2
2 x 2.5 mm
2
2
3 x 0.5 mm
2
2
2 x 0.5 mm
2
2
2 x 0.5 mm
2
2
4 x 0.5 mm
2
2
3 x 0.5 mm
2
2
2 x 0.5 mm
2
2
2 x 0.5 mm
2
2
EN
17

Publicidad

Tabla de contenido
loading

Tabla de contenido