EN
4 - prODUCT INsTAllATION
4.1 - electrical connections
WARnInG - before making connections, verify that the installation is not powered
MOTOR COnnECTOR
Terminal block for power connections, for 24Vdc motor and
encoder
M-
Motor power (red or brown)
M+
Motor power (green or white)
GnD
Encoder (white)
EnC
Encoder signal output (green or blue)
+5V
Encoder power; (brown or red)
SW5 SWITCH
Set at "On" disables CO, F2, F1, ST inputs.
Eliminates the need to jump the inputs on terminal block.
WArNING - connected safeties are excluded with
dip switch ON
n
L
1 2
24Vac/dc
- +
18
On
M
Motor
encoder
T2A 230V
230Vac
50/60Hz
3
1 2
3 4
24Vac/dc
- +
nC
TX
RX
F2
POWER COnnECTOR
+Vac
Transformer Power 24÷26 Vac (12 A peak)
-Vac
Transformer Power 24÷26 Vac (12 A peak)
Grounding
CR
Courtesy light, +24 V to be connected to "C", 25 W
max
C
Common for outputs "CR" and "LA"
LA
Flashing, +24 V to be connected to "C", 25 W max
-
Common for outputs "+24" and "SCA"
+24
Stabilized output, 24 V, 300 mA max, tolerant to short-
circuit
M-
M+
GnD
EnC
+5V
1 2
3
24Vac/dc
- +
TX
1 2
3 4
24Vac/dc
- +
nC
RX
F1