When "Disinfection" has been activated, if communication error with the indoor unit or malfunction of the water tank heater occurs, it will
automatically quit.
The setting is memorized and re-proposed in case of power failure (see 2.6.1 On/Off memory).
The default value is Off.
2.2.10 Clock Timer
At the function setting page, by touching "Clock timer", it will go access to the "Clock timer" setting page.
At the "Clock timer" setting page, it can be set to "On" or "Off".
The options are:
"Mode" is used to choose the desired mode (Cool/Heat/Hot water/Cool+Hot water/Heat+Hot water);
o
"Period" is used to for time setting (Star timer/End timer);
o
"T-water tank" is used to set the temperature of the hot water tank (if present).
o
"WOT-Cool"/"WOT-Heat" is used to set the supply water temperature.
o
After that, by touching the "Save" icon, all settings will be saved.
NOTE
"Timer" is a non-repetitive daily timer.
The "ACS" mode within the "Timer" function can only be activated if "DHW tank" has been set to "Active": otherwise the operating
modes allowed are only "Heating" and "Cooling".
When the water tank is available, "Heat", "Cool", "Hot water", 'Heat + Hot water" and "Cool + Hot water" are allowed;
however, when the water tank is unavailable, only "Heat" and "Cool" are allowed.
When the end time is earlier than the start time, this setting is invalid.
Water tank temperature can be set only when "Hot water" is involved in the operation mode.
The priority of the timers is as follows: Time bands (high) - Timer - Preset mode - Weekly timer (low)
The setting is memorized and re-proposed in case of power failure (see 2.6.1 On/Off memory).
The default value is Off.
2.2.11 Temp. Timer
At the function setting page, by touching "Temp.Timer", it will go access to the "Temp.timer" setting page.
This function allows to program the water delivery set point in time.
At the "Temp.timer" setting page, it can be set to "On" or "Off".
< Save
< Cancel
< Save
41
ELECTA-ECO