INSTALLATION INSTRUCTIONS
Connecting electric dryers (cont.)
USA only
WARNING
wire should be connected to same color screw. Wire color
indicated on manual is connected to the same color screw
in block. Failure to follow these instructions may result in a
short or overload.
prohibit grounding through the neutral conductor.
Three-Wire Connection for Electric Dryers:
Power Cord
the dryer. Install a UL-listed strain relief into the power cord
through-hole; then thread a UL-listed,
conductor power cord through the
strain relief.
UL-Listed
Cord
Terminal
Block
UL-Listed
Strain Relief
minimum copper conductor and closed loop or forked
terminals with upturned ends.
terminal block screws. Attach the neutral wire to the center
terminal block screw. Connect the external ground (if required
by local codes) to the green ground screw.
. Reinstall the terminal block access cover.
Hot
Neutral
(Black)
(White)
Ground
Screw
Power Cord
Ground Wire
Hot
(Red)

Publicidad