LG DLEX6001W Manual Del Propietário página 25

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connecting electric dryers (cont.)
USA only
WARNING
wire should be connected to same color screw. Wire color
indicated on manual is connected to the same color screw
in block. Failure to follow these instructions may result in a
short or overload.
prohibit grounding through the neutral conductor.
Three-Wire Connection for Electric Dryers: Direct Wire
the three wires into a hook shape.
the dryer. Install a UL-listed strain relief into the power cord
through the strain relief.
UL-Listed
Cord
Terminal
Block
UL-Listed
Strain Relief
INSTALLATION INSTRUCTIONS
cable.
reinstallation of the dryer.
terminal block screws. Attach the neutral wire to the center
terminal block screw. Connect the external ground (if required
by local codes) to the green ground screw.
. Reinstall the terminal block access cover.
Hot
Neutral
(Black)
(White)
Ground
Screw
Ground Wire
25
conductor
Hot
(Red)

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Dlgx6002wDlex6001vDlgx6002v

Tabla de contenido