Param.
Description
P0404 Motor Rated Power
P0405 Encoder Pulse Number
P0406 Motor Ventilation
P0407
Motor Rated Power
Factor
P0408 Run Self-Tuning
P0409 Stator Resistance
P0410
Magnetization Current
P0411
Leakage Inductance
T
Time Constant
P0412
r
T
Time Constant
P0413
m
P0680 Status Word
16 | CFW700
Adjustable Range
0 = 0.33 HP 0.25 kW
1 = 0.5 HP 0.37 kW
2 = 0.75 HP 0.55 kW
3 = 1 HP 0.75 kW
4 = 1.5 HP 1.1 kW
5 = 2 HP 1.5 kW
6 = 3 HP 2.2 kW
7 = 4 HP 3 kW
8 = 5 HP 3.7 kW
9 = 5.5 HP 4 kW
10 = 6 HP 4.5 kW
11 = 7.5 HP 5.5 kW
12 = 10 HP 7.5 kW
13 = 12.5 HP 9 kW
14 = 15 HP 11 kW
15 = 20 HP 15 kW
16 = 25 HP 18.5 kW
17 = 30 HP 22 kW
18 = 40 HP 30 kW
19 = 50 HP 37 kW
20 = 60 HP 45 kW
21 = 75 HP 55 kW
22 = 100 HP 75 kW
23 = 125 HP 90 kW
24 = 150 HP 110 kW
25 = 175 HP 130 kW
100 to 9999 ppr
0 = Self-Ventilated
1 = Separated Ventilation
2 = Optimal Flux
0.50 to 0.99
0 = No
1 = No Rotation
2 = Run for I
m
3 = Run for T
m
4 = Estimate T
m
0.000 to 9.999 ohm
0 to 1.25 x I
nom-ND
0.00 to 99.99 mH
0.000 to 9.999 s
0.00 to 99.99 s
Bit 0 to 4 = Reserved
Bit 5 = 2nd Ramp
Bit 6 = Configuration Mode
Bit 7 = Alarm Condition
Bit 8 = Running
Bit 9 = General Enabling
Bit 10 = Forward
Bit 11 = JOG
Bit 12 = Remote
Bit 13 = Undervoltage
Bit 14 = Reserved
Bit 15 = Fault Condition
Factory
User
Propr.
Setting
Setting
Motor
cfg
max-ND
1024 ppr
cfg
0 = Self-
cfg
Ventilated
0.68
cfg and
V V W
0 = No
cfg,
V V W
and
Vector
0.000 ohm
cfg,
V V W
and
Vector
I
nom-ND
0.00 mH
cfg and
Vector
0.000 s
Vector
0.00 s
Vector
Groups
Pag.
MOTOR
10-4
11-12
MOTOR
11-12
MOTOR
10-4
11-13
MOTOR
10-4
11-13
MOTOR
10-4
11-13
11-20
MOTOR
10-4
11-13
11-21
MOTOR
10-4
11-13
11-22
MOTOR
11-13
11-22
MOTOR
11-13
11-23
MOTOR
11-13
11-24
ro
NET
17-4

Publicidad

loading