RANSMITTER SETTINGS AND CONNECTIONS
J6
Terminals for the connection of the clean contact of the
mechanical or inductive safety edge.
SWTX Micro-switches for coordination and identification
JP3
Strip enabling/disabling jumper (standard jumper not inserted for
unconnected strip. Disable the jumper if a strip is connected)
JP4
Strip contact selector jumper NO/NC (factory setting NC)
JP5
Range selector jumper 13/25 m (factory setting 25 m)
BAT
Alkaline batteries 2 x AA 1,5V
DLTX
Green LED function indicator
NOTE: EACH TIME A NEW JUMPER CONFIGURATION IS USED IT IS NECESSARY TO TURN OFF AND TURN ON POWER TO BOTH THE
TRANSMITTER AND THE RECEIVER.
BAT
JP5
JP3
JP4
R
EFERENCE TO STANDARDS FOR AUTOMATIC GATES AND
DOORS
The installer must ensure that the installation of the NOVA Wi-Fi photocells is
performed only in the presence of further protection as specified by standard
EN12453 in 5.5.1. (general protection requirements).
RIB MAY NOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED BY
IMPROPER, WRONG OR UNREASONABLE USE.
Usage restrictions: The NOVA Wi-Fi photocells cannot be used on devices
excluded by the application of the EN12978, such as:
- protection devices for the installation on doors used for a different purpose to
those ones used for pedestrian or veheicle access, covered by the norm which
principal intent is that of allowing a safe access to industrial, commercial, public
and commercial sites. Some examples of excluded accesses can be: sluice
gates, dams, lift doors, vehicles' doors, doors used mainly to restrain animals,
theatre curtains, railways barriers, barriers used only for vehicles.
- Devices used only fo the standard control and for the stopping, including the
emergency stopping, of motorized doors.
- Safety systems and safety devices used on machineries different from doors.
ATTENTION: Any possible modification of the device, or of the configuration
of the same cannot be carried out without the clear authorization by the
manufacturer or, by the local authorized dealer.
The installer of the safety device must make sure that the end user know the
R
ECEIVER SETTINGS AND CONNECTIONS
J7
SWRX
S3 PROG. TX Push-button for memorization and alignment
JP6
JP7
JP8
BAT
DLRX
BAT
DLTX
JP7
SWTX
JP6
J6
JP8
S3
following:
- That the safety devices must be made known to all appropriate people.
- That the passages to reach the devices must be kept clear from any obtsacle.
- About the procedures for cleaning so to avoid the dangerous building up of
material.
- The possible details for a restart of the system after an emergency or accidental
stop caused by the control system.
Any modification of the project or, of the configuration of the device, without
discussing it first with the manufacturer or with the local autorized dealer can
cause dangerous situations.
U
SES
NOVA Wi-Fi photocells communicate constantly and exclusively with the
MASTER Wi-Fi card and completely meet the active security demands of all
types of automatic opening systems.
WARNING: If you remove the power of the MASTER Wi-Fi for a long time,
the TOUCH Wi-Fi safety strips and the NOVA Wi-Fi photocells will exhaust
faster than normal the charging of their batteries. Keep the MASTER Wi-Fi
always properly fed to ensure a period of three years for the batteries-life,
as stated by RIB.
If for instance, the power to the system is cut off every night, the photocells
and the safety strips will regularly and constantly search for the MASTER
Wi-Fi without finding it. Therefore, the life span of the batteries may be
14
14
14
14
Terminals for the connection of the clean contact of the
mechanical or inductive safety edge.
Micro-switches for coordination and identification
Strip enabling/disabling jumper (standard jumper not
inserted for unconnected strip. Disable the jumper if a strip
is connected)
Jumper wire for photocell or strip selection (factory setting
OFF)
Strip contact selector jumper NO/NC (factory setting NC)
Alkaline batteries 2 x AA 1,5V
Red LED indicating correct power and infrared signal
alignment
DLRX
SWRX
J7