Axis A1001 Guia De Instalacion página 22

Ocultar thumbs Ver también para A1001:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AXIS A1001 Network Door Controller
3–4
Configurable
(Input or
Output)
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either a rated output
power limited to ≤100 W or a rated output current limited to ≤5 A.
Function
Pin
1
0 V DC (-)
2
DC input
Network Connector
RJ45 Ethernet connector. Supports Power over Ethernet (PoE). Use
Category 5e cables or higher.
Function
Power and Ethernet
Digital input — Connect to pin 1 to
activate, or leave floating (unconnected)
to deactivate.
Digital output — Connect to pin 1 to
activate, or leave floating (unconnected)
to deactivate. If used with an inductive
load, e.g. a relay, a diode must be
connected in parallel with the load, for
protection against voltage transients.
Notes
For powering controller when not using
Power over Ethernet.
Note: This pin can only be used as
power in.
Specifications
Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3,
44–57 V DC
Max load on outputs = 7.5 W
22
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA
Specifications
0 V DC
10–30 V DC, max 26 W
Max load on outputs =
14 W

Publicidad

Tabla de contenido
loading