SmarTemp Control
5. Apply the supplied "Heater Off" warning sticker in a highly visible location near the fuel filling
cap. Refer to the example sticker below.
6. Observe the operating section for proper menu setup.
Temperature Calibration
Based on the installation location of the SmarTemp Control, multiple factors such as door openings can
affect the SmarTemp Controls ambient temperature reading. If temperature offset adjustment is needed
see "Offset" on page 5 for further details.
Electrical Connections
This is a plug and play kit for an AT 2000 ST or AT 3900/5500 EVO Heater (refer to the compatibility
section for adaptor part numbers).
Connector Pin out
Pin Number
1
2
3
4
5
6
7
8
For terminal removal use: Molex terminal removal tool P/N: 11-03-0044
Description
+12 / 24V
GND
Heater Output
Diagnostic Blink Code
Analog Output (Temperature Set Point)
Analog Output (Ambient Temperature)
Vent Input
Diagnostic Input W-Bus
http://www.molex.com
Installation - Operating Instructions
TERMINAL INSERT
SIDE OF CONNECTOR
2
Wire Color
Red
Brown
Black or Gray
Orange
Blue
Yellow
Purple
Green