The Wolf warming drawer requires a separate,
grounded 220 – 240 V AC, 50/60 Hz power
supply and must be connected to an individual
properly grounded branch circuit and
protected by a 15 or 20 amp circuit breaker or
I M P O R TA N T
time delay fuse.
N O T E
IMPORTANT NOTE: The warming drawer
must be plugged into a mating 3-prong
You must follow
ground ing-type electrical cord to minimize the
all local codes and
possibility of electric shock.
ordinances when
If the outlet is placed behind the unit, make
installing your
service.
sure the outlet is flush with the back wall. For
location of the electrical outlet, refer to the
installation illustration for your specific
installation on pages 7–13.
If two warming drawers are installed side by
side, they can operate from the same electrical
outlet. A 30 amp circuit breaker is required for
this installation.
14
WA R M I N G D R AW E R
R E Q U I R E M E N T S
In addition, be aware of local codes and ordi-
nances when installing your service.
The electrical outlet must be checked by
a qualified electrician to be sure that it is
wired with the correct polarity. Verify
that the outlet provides 220 –240 V AC
and is properly grounded.
Do not use an extension cord or two-
prong adapter. Electrical ground is
required on this appliance. Do not remove
the power supply cord ground prong.