Care and maintenance
Disassemble and clean the Secuquick softline after each use to ensure it continues to work
safely.
Check that it is working properly before each use: Valves and seals, condition of the cover
closure.
Replace the sealing ring and other seals if they are damaged, brittle, shrunken or cracked.
These parts should be replaced at least every two years or after 400 cooking cycles. All
other interventions may be carried out only by an AMC service center.
Do not modify the Secuquick softline in any way. Do not disassemble the Secuquick softline
any more than necessary for care and maintenance. Improper interference, tampering,
installation of foreign parts or the use of force can impair function and safety.
Do not tamper with or take apart the gearbox. Never use force or tools (e.g. pliers) to open a
blocked gearbox.
Inspecting the gearbox
Check before each use that the gearbox is not stuck. If the gearbox shakes or if the mechanism is
jammed, stop using the Secuquick softline. The product may no longer be guaranteed to be safe. Con-
tact AMC customer service.
Damage or malfunctions
If damaged or malfunctioning, the Secuquick softline must no longer be used. In the event of a
fall, other improper handling or use, hidden damage may also occur. For safety reasons, have the
Secuquick softline checked by an AMC service center.
Magnet
The Visiotherm (cover knob with temperature indicator) is equipped with a magnet to transmit the
temperature. A pacemaker can be switched to test mode and cause discomfort if it is less than 2 cm
from the Visiotherm viewing window. Credit cards, EC cards, data carriers, hearing aids or mechanical
watches can be affected if they are less than 2 cm from the viewing window of the Visiotherm.
Disposal
Do not dispose of the Secuquick softline in household waste. The materials are recyclable. If
necessary, dispose of in accordance with local regulations.