Trouble Shooting - Astralpool MAN14 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Instruction Manual for Infrared Saunas

Trouble Shooting:

Problem
1
Indicator light for power
supply not working
2
Indicator light for function
is not working
3
Infrared Heater not
heating up
4
Malfunctioning of
temperature setting
5
Odor from the sauna
6
Light bulb is not working
Possible Causes
The connector is not connected
properly
The fuse is burned out
The corresponding indicator light is
broken
The circuit board or components are
broken
The heater is broken
Its life will be shorted gradually for
being used for many times
The fuse is burned out:
L-Hand fuse holder: For back panel
R-Hand fuse holder: For front panel
The wire junction is loose or the
heater's wire is loose
The circuit board relay is not
functioning
Some problems with heater
Senor wire is not functioning
The circuit board for temperature
controlling is not function
The circuit problems (fuse holder wire
is loose, junction wire is loose, circuit
board components is broken)
Light bulb is burned out
Light bulb wiring is loose
The light bulb connector is broken
Problems with electrical control panel
14
What To Do
Check the connector or replace a new
one
Change the fuse
Replace the relevant control panel
Replace the circuit board
Replace with a new one
Of the same specifications
Replace with a new one of the same
specifications
Check it, and reconnect them tightly
Replace circuit board
See the 3rd section of heater problem
Re-connect or replace the senor wire
Replace the control panel circuit
board
1) Cut off the power, check the power
supply and voltage;
2) Find the objects with problems
3) Replace the damage parts
Replace light bulb
Check connector or reconnect the
light bulb wiring
Replace it
Repair or replace it

Publicidad

Tabla de contenido
loading

Tabla de contenido