Datalogger
The CX controller provides a built-in datalogger. The datalogger gathers 1 year
performance data of your PV system, including max. and min. battery voltage,
battery state of charge, max. charging current and max. load current, etc. System
performance can be easily analyzed with these historical data, thus helping you
to know your PV system better.
With Phocos CXI computer interface and CXCOM application software, the CX
datalogger can be accessed by a computer. History data can be read and displayed
by CXCOM.

Nightlight Function

The CX controller comes with a sophisticated nightlight function. It controls the
load output at night and is widely programmable.
There are 2 modes available:
DUSK TO DAWN and EVENING/MORNING. The mode can be selected in Programming
Menu 3.