SPIDO SPRING 900 Instrucciones De Uso página 29

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
[
]
Getting started
4. Connect the suction hose
to the pump, using PTFE on the
thread in order to avoid air
breach
5. Connect the outlet to the
pump.
6. Plug the pump to the mains,
and press the knob
7. During the suction process, make sure that nothing is blocking the air
escape from the delivery hose
SPRING 1300E : Electronic functions
SPRING 1300E is equipped with electronic protection:
When priming, in case of dry run for 20s, the LED
(1A) is flashing during 40s. Then pump stops 5s,
and repeat this cycle 3 times.
.
When running normally, Pump controls if there is
water to suck every 30s. If not, the LED (1A) is
flashing. After 20s of dry run, LED (1B) is
lightened and pump safety stop is activated
In case of delivery outlet closed, the LED (1B) is
flashing
Pump continues to run a few minutes before the
safety mechanism stop it: LED (1B) is lightened
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Spring 1100Spring 1300e002070002071002072

Tabla de contenido