Model 75CG
Gas
GB
IE
PT
ES
Type
1
1
1
1
Nat.
Gas
L.P.
Gas
7
7
7
7
NOTE: Follow all instructions including
verification and adjustment of injector pressure.
1 – Order as Regulated Natural Gas. No modification
needed.
2 – Order as Regulated Natural Gas. Apply
appropriate country sticker.
3 – Order as Regulated Natural Gas. Apply
appropriate country and gas stickers.
4 – Order as Unregulated Natural Gas. Apply
appropriate country sticker.
5 – Order as Unregulated L.P. Gas. Apply appropriate
country sticker.
70268201
Input: 48.3 kW
IT
DK
NO
SE
FI
1
2
2
2
2
5
5
5
5
7
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
DE
NL
BE
FR
AT
Family &
Group
2nd family
2
2
Group H
2nd family
3
Group L
2nd family
4
4
Group E+
3rd family
5
5
Group
3rd family
6
6
Group
3rd family
8
8
Group 3+
Table 5
6 – Order as Regulated Natural Gas. Convert with
regulator spring kit Part No. M411334 and (3) 2.0 mm
injectors Part No. M400999. Apply appropriate
country and gas stickers.
7 – Order as Unregulated L.P. Gas. No modification
needed.
8 – Order as Unregulated L.P. Gas. Apply appropriate
country sticker.
OPEN – No Approval available.
Special Cases – Regulated Gas Valve may be
converted to Unregulated with block-open kit Part No.
M400763.
Gas
Inject.
Inject. Qty
Inlet
0
& Part. No.
Press.
2
3.6 mm
20 mbar
M401014
(E)
2
3.6 mm
25 mbar
M401014
(LL)
2
20.25
2.9 mm
M402444
mbar
2
2.0 mm
30 mbar
M400999
B/P
2
2.0 mm
50 mbar
M400999
B/P
2
28.37
2.0 mm
M400999
mbar
Installation
Gvnr./
Inject.
Regltr.
Press.
Yes
8.9 mbar
Yes
12.6 mbar
No
Unreg.
No
Unreg.
Yes
28.5 mbar
No
Unreg.
29

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido