CE Marked Models
Loading door switch is factory adjusted to turn off
when the door is opened a maximum of 3 inches
(76 mm). If adjustment is needed, refer to Figure 21
and follow these steps:
1. Start tumbler, following the operating
instructions which accompanied it.
2. Slowly open loading door. Cylinder and heating
system should stop when door is open 3 inches
(76 mm) maximum.
3. Slowly close loading door while depressing start
switch or pad. Tumbler should start before
loading door is 0.5 inch (13 mm) from fully
closed.
4. If opening the loading door 3 inches (76 mm)
maximum does not stop tumbler, adjust switch.
5. Loose lower screw on switch coupler (use 2 mm
hex wrench).
6. Align screw slot with alignment marks on switch
top (switch should be closed, or on).
7. Start tumbler.
8. Prop door open 2.5 inches (63 mm).
9. Slowly rotate switch coupler counterclockwise
(viewed from above switch) until tumbler stops.
10. Tighten lower screw on switch coupler.
11. Return to step 1 to verify loading door switch
operation.
70268201
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
1
1
Loading Door Switch
2
Screw Slot
3
Switch Coupler
Figure 21
Adjustments
2
3
T495I