Calibration of external room sensor (remote):
This menu is only displayed if parameter rEG (#20) is set
with "Amb". Calibration must be done after a given order
has been operating for a day. Place the thermometer in
the middle of the room at about 1.5 m above the floor.
Record the temperature shown after 1 hour. When you
enter calibration mode for the first time, the indicator says
"no", which means no calibration has been performed yet.
Enter the reading on your thermometer using the key
and
(step of 0.1°C). The setting is validated with key
YES appears to indicate that calibration.
Important note: A large temperature deviation may indi-
cate an inappropriate installation of the thermostat. If the
temperature difference is too big, this could mean your
thermostat was not installed properly e.g. in the right place.
NOTES: If user press simultaneously the keys
sensor calibration is reset. No is displayed.
Default value: no for offset of 0.0°C
for offset included between -3.0°C and 3.0°C
Open window detection:
"Yes": activation of function
"no": no activation
More information is in paragraph "Opened window detection"
Default value: Yes
Operating mode of thermostat:
- Hot: heating mode
- CLd: cooling mode
- rEv: activation of reversible menu
- Aut: automatic mode
This parameter menu appears only if digital thermostat
isn't associated with a Touch screen BT-CT02 or a 6Z
master.
Authorization or not of cooling mode:
This parameter menu appears only if digital thermostat is
associated with a Touch screen BT-CT02 or a 6Z master.
It permits to allow or not cooling system in remote room.
Factory setting value: Yes
PIN code activation:
"Yes": activation of function
"no": no activation
More information is in paragraph "code PIN description"
Factory setting value: no
Range values: Yes:
Values: Yes / no
Other values: no
Values: Yes
.
and
,
13