n
PREPARE THE HOOD
TEFLON
®
-
COATED
BOTTOM
COVER
(Held in
place with
2 screws)
IT
3
Remove Teflon
cover and mounting screws aside.
Teflon
®
is a registered trademark of DuPont.
4
Remove Damper/Duct Connector from inside the hood.
Set connector aside - with mounting screws and parts bag.
5
Remove either top or back wiring knockout and install
approved Electrical Cable Clamp.
®
(Continued)
®
-coated bottom cover from hood. Set
ELECTRICAL
CABLE CLAMP
PREPARE THE HOOD
NOTE
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼" x 10"
Vertical & for 7" Round
Discharge)
DAMPER/
DUCT
CONNECTOR
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼" x 10"
Horizontal Discharge)
6
Remove appropriate Duct Knockout(s) from top or back of
hood.
SCREW
METAL STRIP
7
Horizontal Discharge Only: Remove the Plate in front of the
horizontal discharge knockout. Cut the Ties, lift plate out, and
discard plate. DO NOT REMOVE the Metal Strip held in place
with two Screws.
ALLURE
If hood is to be installed Non-Ducted:
•
Purchase a set of (2) Non-Ducted Filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
•
Skip to "CONNECT WIRING" section on page 4.
DUCT KNOCKOUT
(Remove for 7" Round
TIES
PLATE
®
QS2 SERIES
RANGE HOOD
Page 3
(Continued)
SEMI-CIRCULAR
Discharge)