Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Spirali HDR Panzer - Issue 00
ATTENTION! : if the cursor is positioned beyond the first character of the message
and you press A to return to the main menu, the message will be cut in the position
corresponding to the cursor; therefore move the cursor to the end of the message
before exiting.
N.B. It is advised to write the message on a piece of paper using the codes of the table (spaces included)
and then to programme it into the machine.
Command 96 Inputs user message 2 (max 63 characters):
The command allows the second message that can be modified by the owner to be input. This message is
displayed in STANDBY when the payment system cannot give change.
The instructions for inputting the message are the same as those given for the previous command.
Command 97 Enables user message 1 display:
By setting this command at 1 when the machine is in STAND-BY and the payment system is able to give
change, message 1programmed by the owner with command 95 is displayed.
If the command is set at 0, the standard message is displayed.
Command 98 Enables user message 2 display:
By setting this command at 1 when the machine is in STAND-BY and the payment system is unable to give
change, message 2 programmed by the owner with command 95 is displayed.
If the command is set at 0, the standard message is displayed.
Command 99 Displays error events:
It displays the last 20 error events; press pushbutton B to pass from one display to another.

ERROR CODE

01
Nr. selection code
02
Nr. selection code
05
Nr. selection code
TEST 10
TEST 11
TEST 13
16
30
31
32 ÷ 38
In particular conditions (of temperature and humidity), the photoelectric cells could
mist over when the door is opened. In this case, after the door is closed the machine
will signal an error (Error 31) and for a few minutes operation of the photoelectric cells
will be disabled.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
SUB-CODE
/
Upper temperature probe fault (check that the setting of
command 50 is consistent with the model of the machine).
/
/
/
Communication error between photoelectric cell board and
/
/
/
MEANING
Motor blocked (the spiral does not rotate)
The spiral does not complete the rotation
Motor disconnected
Lower temperature probe fault
Evaporator temperature probe fault
main board
Fridge safety device intervention
Photocell test error .
Photocell calibration error
27
E
N
G
L
I
S
H

Publicidad

Tabla de contenido
loading

Productos relacionados para FAS International SPIRALI HDR

Este manual también es adecuado para:

Spirali hdr panzer

Tabla de contenido