RISK OF INDOOR AIR POLLU-
WARNING
TION!
CARBON MONOXIDE POISONING
DANGER
MAY LEAD TO DEATH!
The products described in this manual are
propane direct-fired, forced air heaters. Propane
forced air heaters are primarily intended for
use for temporary heating of buildings under
construction, alteration or repair. Direct-fired
means that all of the combustion products of the
heater enter the heated space. This appliance
is rated at 98% combustion efficiency, but does
produce small amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation in
accordance with the instructions in this manual
can result in death.
People with breathing problems should consult a
physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the flu. Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea
Sore Throat
Burning of Nose and Eyes
•
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more affected by carbon monoxide than
others. These include: pregnant women, those with
heart or lung problems, anemia or those under the
influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED
ONLY FOR: The temporary heating of adequately
ventilated buildings or structures under
construction, alteration or repair! Provide at least a
three square foot (2,800 sq cm) opening of outside
air for every 100,000 Btu / Hr heater rating. Refer
to "Ventilation" on page 10 for further instructions.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED
®
SAFETY INFORMATION (CONT.)
Dry Mouth
•
TO A FUEL SOURCE
PROPANE IS AN
DANGER
EXPLOSIVE GAS.
WHAT TO DO IF THE SMELL OF GAS IS PRESENT:
– DO NOT attempt to light the heater.
– Extinguish any open flame.
– Shut off gas to heater.
– If odor continues, contact your local gas
supplier or fire department.
– DO NOT touch or use any electric switch or any
electric device that can cause a spark.
– Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
– If you can not reach your gas supplier, call the
fire department.
– Service must be done by a qualified service
agency.
RISK OF BURNS, FIRE AND
WARNING
EXPLOSION!
NEVER store or use gasoline or other flammable
vapors and liquids in the vicinity of this heater.
NEVER store a propane (LP) cylinder not connected to
this heater in the vicinity of this heater.
NEVER connect heater to an unregulated gas supply.
NEVER obstruct the flow of combustion and
ventilation air.
NEVER use duct work in front or rear of heater.
NEVER modify this heater or operate a heater that
has been modified.
NEVER service, move or handle heater while still hot
or operating
Keep all combustible materials away from this heater.
CAUTION! HOT WHILE IN
WARNING
OPERATION. DO NOT TOUCH.
KEEP CHILDREN, ANIMALS, CLOTHING AND
COMBUSTIBLES AWAY FROM HEATER.
Minimum Clearance From Combustibles
Sides
48 in.
3
Convection Heater User's Manual
Top
96 in.