GOK SmartBox 1 Instrucciones Par El Montaje Y La Operación página 24

Indicador electronico de contenido - opcional con funciones adicionales
Ocultar thumbs Ver también para SmartBox 1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Menu
Input function
4.Tank
Adjust the tank volume with [+] / [-] (100%). The default
volume
setting is 0 L. The value must be set.
Free space: YES Free space[%]
Free space: NO
5.Tank
Enter inner tank height in millimetres: e. g.: 249 cm
height
(max. value = 999,9 cm) (height without dome)
REFERENCE
Steps 6 + 7 are only required for SmartBox
Menu
Input function
6.Relay 1
Switch function of relay 1 or buzzer:
or
Deactive
 SmartBox 2
Active
ON
OFF
Example of switch point setting for Active (with
hysteresis):
Enter switching points as % values from 01-99 (and/or
enter as °C value from -99 to +99 only for probe with
6.Acoustic
temperature measurement)
alarm
deactive  activate with [+] / [-] to
(Buzzer)
 SmartBox 3
active
On 10%
Off 12%
On +0°C
Off +0°C  OFF: set with [+] / [-]
Deactivate the relay or buzzer via deactive or input
of 0% or 0°C (for On and Off).
7.Relay 2
See 6. Relay 1 for the data for Relay 2
 SmartBox
2+3
8.Exit
Press [Enter] to return to display mode
After performing entry steps 1 - 7, the programming process is completed. After confirmation
of step "8.Exit", the device automatically returns to default display mode; the current tank
content is shown in the display.
Special functions are available under entry steps 9 to 24.
8 / 16
SmartBox
Please see a volume table for the highest value,
if available. For a 100 m³ cyl. buried tank, this
may for example be the value 100600 litres.
Please see a volume table for the highest value,
if available. For a 100 m³ cyl. buried tank, this
may for example be the value 288 cm.
The relay does not switch in relation to
the content
The relay switches in relation to the
content
Forces the relay to energise (fix ON)
Forces the relay to de-energise (fix OFF)
 press Enter to confirm 
 ON: set with [+] / [-]
 OFF: set with [+] / [-]
 ON: set with [+] / [-]
®
1 / SmartBox
®
®
2 and SmartBox
 [Enter]
 [Enter]
 [Enter]
 [Enter]
®
2 / SmartBox
Input value
___________L
_________mm
3
Input value
ON ______%
OFF ______%
ON ______°C
OFF ______°C
ON ______%
OFF ______%
ON ______°C
OFF ______°C
Part No. 28 100 57 e
®