TROUBLESHOOTING
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK AND INJURY FROM MOVING PARTS UNPLUG BEFORE CLEANING OR SERVICING.
Issue
Possible Cause
Reduced or no spray
1. Solution tank is empty
2. Solution tank not fully installed
3. Clogged Solution Nozzle
Loss of suction
1. Dirty water tank not installed properly
2. Dirty water tank is full
3. Brush roll cover is not installed properly
4. Nozzle hose behind brush roll is clogged
5. Filter is clogged
6. Dirty water tank screen is clogged
1. Handle is not reclined
Brush roll not turning
2. Brush roll is not installed properly
3. Brush roll is obstructed
Suggested Solution
1. Refill solution tank
2. Turn power OFF, reinstall solution tank until snug
3. Follow instructions as shown in the Cleaning the Brush Rroll and Nozzle section. Remove brush roll cover. Submerge spray nozzle in
solution-water mixture and let soak overnight, making sure spray tip is fully submerged (Use mixture of 2 oz solution per quart of water).
Gently scrub with water, dry and reinstall
1. Turn power OFF, remove and reinstall dirty water tank. There will be an audible "click" when tank locks into place.
2. Turn power OFF, empty and reinstall dirty water tank
3. Turn power OFF, remove brush roll cover, reinstall brush roll and cover according to instructions on page 12
4. Turn power OFF, follow instructions for care of brush roll and cover on page 12
5. Clean and allow filter to dry completely
6. Clean float screen in the dirty water tank. Twist the screen counter-clockwise to remove from tank lid. Rinse thoroughly and replace by
aligning grooves and twisting clockwise to secure on tank lid
1. Recline handle and turn power ON to allow brush roll to rotate
2. Turn power OFF, follow instructions for care of brush roll and cover on page 12
3. Turn power OFF, follow instructions for care of brush roll and cover on page 12. Ensure brush roll is free of hair and debris
15