7.u - ADVICES FOR CORRECT USE
• DO NOT bring cloths soaked with Alcohol, Acetone, Ammonia,
Bleach or Solvents into the proximity of the appliance.
• DO NOT use any kind of SPRAY near the gas detector.
• DO NOT carry out an operational test on the gas detector by
releasing gas directly from the gas pipe, lighters or lighter refill
cans.
• Cooking vapours and pollutant dusts can affect the
performance of the sensor over time.
• DO NOT ATTEMP TO OPEN THE CABINET: danger of electric
shock and malfunctions.
• On a periodic basis, check that the vents on the front panel of
the detector, which channel air to the sensor, are not
obstructed by dust or grease, etc.
• To clean this device make use of a lightly wet tissue.

INSTALLATION INSTRUCTIONS

surface mounted

OVERALL DIMENSIONS

82
ON
TEST
RESET
120
1.i - INSTALLATION OPERATIONS
CURRENTLY NATIONAL STANDARDS ENFORCEABLE IN THE INSTALLATION
COUNTRY COVERING THE INSTALLATION AND USE OF GAS POWERED
EQUIPMENT ARE TO BE RESPECTED, AS ARE STANDARDS COVERING SMOKE
DISPERSION AND VENTILATION OF ENCLOSED AREAS, EVEN THOUGH GAS
DETECTION EQUIPMENT IS INSTALLED.
max 30 cm
Natural gas detector
LPG detector
max 30 cm
Install
Install
Install detectors from 1 to 4 m from gas appliances.
Do not install the detectors outdoors or in places exposed to atmospheric agents.
Do not install the detectors near: sink, air vents, HVAC appliances or windows;
furthermore, the detectors must not be installed in enclosed spaces, such as
semi flush mounted
behind a curtain or inside a closet.
(with optional support may
Note: in residential units with several
be purchased separately
)
floors, communicating with each other,
additional gas detectors must be
installed.
Fig. 12
Example of installation with 3 gas
detectors connected through BUS.
A - Main unit with solenoid valve control.
B -
Remote unit
C -
Remote unit
40
27,5
min. 1 m
max. 4 m
ON
TEST
RESET
ON
TEST
min. 1 m
ON
ON
TEST
RESET
max. 4 m
Natural Gas
detector
max. 30 cm from ceiling .
LPG
detector
max. 30 cm from floor
.
ON
TEST
RESET
BUS
A
1
Solenoid valve
2
ON
TEST
RESET
RESET
ON
TEST
RESET
TEST
RESET
ON
TEST
RESET
Fig. 11
ON
TEST
RESET
C
BUS
ON
TEST
RESET
B
Boiler