OPERATION
NOT_PRO_OEM-00
Modes and display scenarios
MODE
MEANING
Charger powered
on and/or Chan-
INITIALIZATION
ge of charging
cycle
Batteries in re-
ABSORPTION
charging phase
PHASE
(charge from 0 to
80%)
Batteries in re-
charging phase
(charge from 80%
EQUALIZA-
to 100%)
TION
End of the equali-
PHASE
sation cycle within
a period of 30
minutes
Charging cycle
FLOATING
completed
PHASE
(charge at 100%)
Mains voltage
fault, excessively
high or abnormally
low
MAINS
VOLTAGE
Immediate auto-
FAULT
matic restart,
subject to
disappearance of
the fault
Excessive charger
temperature fault
Automatic restart
CHARGER
after a
TEMPERATURE
min delay
FAULT
of 30 seconds,
subject to
disappearance of
the fault
FLASHING
SOLID LED
LED
All LEDs
for 3
-
seconds
POWER ON
-
BOOST
POWER ON
-
ABS
POWER ON
ABS
POWER ON
-
FLOAT
POWER
-
ON
TEMP
-
OPERATION
NOT_PRO_OEM-00
MODE
MEANING
Excessive battery
temperature fault
BATTERY
Automatic restart
TEMPERATURE
after a min delay
FAULT
of 30 seconds,
subject to
disappearance of
the fault
External tempera-
ture sensor fault
BATTERY
Automatic restart
SENSOR
after a min delay
FAULT
of 30 seconds,
subject to
disappearance of
the fault
Charging voltage
fault, excessively
high or abnormally
low
OUTPUT
VOLTAGE
Automatic restart
FAULT
after a min delay
of 60 seconds,
subject to
disappearance of
the fault
Output fuse fault
OUTPUT
Restart following
FUSES
a mains reset,
FAULT
subject to
disappearance of
the fault
CAN
secure load
FAULT
UK
FLASHING
SOLID LED
LED
-
TEMP
TEMP
-
BAT
BAT
-
FUSE
-
TEMP
-
BAT
FUSE