Product Safety Information
Intended Use:
This Air Impact Wrench is designed to remove and install threaded fasteners.
For additional information refer to Air Impact Wrenches Product Safety Information
Manual Form 04580916.
Manuals can be downloaded from www.ingersollrandproducts.com.
Power Management System
For models that include a power management system, the system allows operator reduction of
maximum output power.
To adjust the power, rotate the Power Regulator to the desired level indicator. The power level
indicators are for reference and DO NOT indicate a specific power. The power output can be
further reduced in forward or reverse by using the variable throttle.
Product Specifications
Model
Type of Handle
216B
Palm
Impacting Sound Level dB (A)
Model
† Pressure (L
216B
90.0
† K
= 3dB measurement uncertanity
pA
‡ K
= 3dB measurement uncertanity
wA
* K
= Vibration measurement uncertanity
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a
properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any hose
coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 46807442 and table on page 2. Maintenance frequency is shown in
circular arrow and defined as h=hours, d=days, and m=months of actual use. Items identified as:
1. Air filter
2. Regulator
3. Lubricator
4. Emergency shut-off valve
5. Hose diameter
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
46806618_ed1
Drive
Impacts per Min.
inch
3/8" sq.
(ISO15744)
)
‡ Power (L
)
p
w
101.0
Recommended Torque Range
1600
Free speed Sound Level dB (A)
(ISO15744)
† Pressure (L
)
‡ Power (L
p
94.8
6.
Thread size
7.
Coupling
8.
Safety Air Fuse
9.
Oil
10. Oil
ft-lbs (Nm)
15-160 (20-217)
Vibration
(ISO28927)
m/s²
)
Level
w
105.8
5.2
EN
* K
1.0
EN-1