Wiring Requirements (cont.)
Preferred Connection
Determine the electrical outlet location. The electrical outlet
should be located within 12" (30.5 cm) of the toilet to
accommodate the length of the power cord. An extension cord
cannot be connected to the seat's power cord.
Route the electrical wires, then install and ground the electrical
outlet. This electrical outlet must be a dedicated, nominal 120
VAC, 60 Hz circuit protected by a minimum 15 A Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Do
not insert the plug into the electrical outlet at this time.
Temporary Connection
NOTICE: Unless the cover screw is grounded through the house
wiring, attaching the adapter grounding screw tab to the cover
screw will NOT ground the unit. If there is any doubt whether
cover screw is grounded, have it checked by a qualified electrician
or service professional.
A temporary connection with a two-prong adapter may be made
where local codes permit, provided that the adapter is grounded.
1097712-5-A
8
Kohler Co.