CAUTION AND WARNING

To prevent in ury and damage to your scale, please follow these instructions very carefully.
Do not transport the scale while the platform is loaded.
For accurate weighing the scale must be placed on a flat, stable surface.
For accurate weighing, verify proper operation according to the procedure described in this
manual before each use.
Do not use in the presence of flammable materials.
Operating at other voltages and frequencies than specified could damage the equipment.
If the LOW BAT indicator activates, for accurate weighing, replace the batteries or connect
the scale to an AC power source as soon as possible.
It is intended that this equipment be used with assistance of a health care worker.

SPECIFICATIONS

GENERAL
Health o meter's Pro Plus
sophisticated microprocessor technology. Each precision instrument is designed to provide
accurate, reliable and repeatable weight measurements and features that make the weighing
process simple, fast and convenient.
The scale is set up to use motion sensing weighing technology, to determine the actual weight
of a moving patient. The scale may be changed to measure live weight see page 18 for
instructions on changing the scale setting.
The weight can be displayed in pounds (decimals, fractions of a lb or lb o ) or in kilograms. The
1100KL features a wrap around handrail for patient comfort and safety and a 1 0 degree
swivel pivot head for reading from either side of the scale. Also included on the platform scales
are two wheels for easy mobility.
The unit can be operated using its AC adapter or by

SCALE SPECIFICATIONS

Capacity and Resolution
2650KL & 2700KL
1100KL
Power Requirements
Environmental
TM
Electronic Scales Models 1100KL, 2650KL and 2 00KL use highly
1,000 Lb x 0.2 Lb / ¼ lb / 4 oz
700 Lb x 0.2 Lb(310 Kg x 0.1 Kg) for 1100KL
Adaptor model ADPT31*(USA-CSA only) 120 VAC-9VDC
60Hz (INCLUDED) or 6 D cell batteries. Adaptor model
ADPT30*(IEC)120-240 VAC-9VDC 50-60Hz (NOT
INCLUDED)
Operating temperatures: 50°F to 95°F (10°C to 35°C)
Storage temperatures: 30°F to 125°F (0°C to 50°C)
Humidity: 85%
D cell batteries (not included).
(454 Kg x 0.1 Kg)