Battery Charger; Replacing The Fuse - Bruno SRE-2010 ELITE Manual Del Operador

Ocultar thumbs Ver también para SRE-2010 ELITE:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BATTERY CHARGER

LEDS
charging
ready
power
on

REPLACING THE FUSE

fuse
charger power switch
©Bruno Independent Living Aids, Inc.
RED
YELLOW
ON
ON (< 1 sec.)
OFF
ON (<5 sec.)
ON (<5 sec.)
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
BLINKS
ALTERNATELY
BLINKS
BLINKS
ALTERNATELY
ALTERNATELY
ON
OFF
®
GREEN
BLUE
OFF
OFF
ON (<5 sec.)
OFF
BLINK (5 sec.)
OFF
OFF
OFF
OFF
OFF
ON
OFF
BLINKS
OFF
ALTERNATELY
OFF
OFF
FAST BLINK
OFF
ON
If the charger is subject to a power line
surge, the AC input fuse may blow. Refer to
the illustration to the left for fuse location.
To replace fuse:
1. Turn OFF the battery charger power
switch.
2. Remove power cord from wall outlet.
3. Twist the fuseholder cap and pull out to
remove the fuse.
4. Replace with the same size and type
fuse: (Bussmann GMD-2A or equivalent)
2A, Slo-Blow, 5 x 20mm.
14
STATUS
charger not connected to battery
battery disconnect situation
detected; 5-second delay until
yellow and green LED's
completely off
charger delivering maximum
current (2.2A)
charger at maximum voltage;
current continues to drop
batteries fully charged;
yellow LED occasionally turns off
low voltage indication
battery defective or heavily
sulfated
partially open circuit; bad
contact or battery sulfation
battery connector reversed
SRE-2010 OPERATOR 02-08-2019