Descargar Imprimir esta página

B - The Options; Flushing System (Automatic Rinsing); Separation Kit; Remote Panel - Aqua-Base XA Serie Manual De Utilización

Publicidad

Idiomas disponibles

Idiomas disponibles

1 – FLUSHING SYSTEM (AUTOMATIC RINSING)
Allows an easy flushing of the membranes, just by switching on the flush system (32). Connecting on the network of water under pressure of
the boat..
See explanation of functioning Chapter C – 4.
Assembling.
- Connect correctly the automatic valve before the filter (see
Installation on board with option flushing page 50).
The fresh water return of the storage tank of the boat must be
imperatively under pressure : 2 bar mini (3 bar maxi).
- Remove the hood (15 : see page 53) of Aquabase and connect
the connecting wire to the electric box : connector 8P (39) see
Control box in ANNEXES page 55,
- Reinstall the hood of Aquabase.
See the On board installation XA with the flushing system in ANNEXES page 50.
2 – SEPARATION KIT
This extra (Ref.102121-10) insures installation of the R/O module, being separated from the main module.
Assembling.
The R/O module is installed using the supplied
supports in any position, vertical or horizontal, as
long as the pressure valve is accessible and the
gauge is readable.
Connection.
- Connect the flexible hose (60) on the HP outlet of the pump, and on the R/O module inlet. Tighten the fitting energetically with two spanners.
Do not use watertight paste or Teflon during assembling of the HP flexible hose.
- Connect the HP hose on the pump and on the R/O module, tighten with a spanner.
- Connect the R/O module produced water outlet (hose 63) to the reject valve (10) inlet with a 8x10 tube.
See the Installation drawing in ANNEXES page 51.
3 – REMOTE PANEL
This extra insures control and surveillance of the AQUA-BASE unit at a distance from the unit, chart table, main electrical panel.
Composition.
The remote control is composed of a built-in remote box and its connecting wire.
Assembling.
- Put the remote box in place, see the drawing in ANNEXES page 54.
- Remove the hood (15 : see page 53) of Aquabase and connect the connecting wire to the electric box : connector 8P (39) see Control box in
ANNEXES page 55.
- Open the electric box and remove the shunt between terminals 3 and 9.
- Shut the main electric box and reinstall the hood.
WARNING : SHUNT BETWEEN TERMINALS 3-9 TO REMOVE IF REMOTE PANEL
See the remote panel in ANNEXES page 54-55.
B – THE OPTIONS
Composition.
Rep
60
61
63
J:\Etude-3d\Aquaset\0-DOSSIER TECHNIQUES\1-sw-plaisance\AQUA-BASE X 2008\09-Manuel utilisateur\AQUABASE XA FRUKES 02-2009-D.doc
Reference
Description
711029
Flexible M6 X 2000
701079
Bracket
717276
HP hose 8 X 13
719107
HP hose 8 X 10
Qty
1
2
2 m
2 m
FR/UK/ES Page 23/23
VERSION 2009-02-D

Publicidad

Capítulos

loading

Productos relacionados para Aqua-Base XA Serie

Este manual también es adecuado para:

Xa111Xa112Xa113Xa221Xa222Xa223