The AQUA-BASE unit must be regularly maintained in order to avoid the occurrence of defects, which could affect its efficiency, its operation
and its reliability. The intervals between maintenance of the AQUA-BASE unit depend on the frequency and conditions of use.
1 – MAINTENANCE SCHEDULE
OPERATION
Replacement of filter cartridge

Replacement of the belt

Checking oil level
Cleaning the prime filter
Oil change
Cleaning the cell
Cleaning the membrane(s)
Checking pressure of the dampner
On this basis the user will adapt his own maintenance schedule, which will depend on his personal use of the unit.
2 – SPARE PARTS FOR ONE YEAR
The spare parts set, for one year AQUA-BASE, Ref 752046-7, contains all the necessary parts for servicing the AQUA-BASE watermaker
unit.
QTE/QTY
REFERENCE
4
711014
1
752038
3
752039
1
752037-EXP10
3 – REPLACEMENT OF THE FILTER CARTRIDGE (Unit stopped)
1.
Stop the unit by pressing OFF (31).
2.
Close the hull valve (V0).
3.
Open the filter by unscrewing the tightening nut using the filter spanner.
4.
Free the used cartridges by setting down the filter bowl.
5.
Replace the used cartridges with a genuine new one (see colours).
6.
Wipe and lightly oil the seal with food fat.
7.
Reset the filter after having checked the cartridge position.
8.
Screw the tightening nut by hand.
4 – REPLACEMENT OF THE BELT
- Loosen the 4 pump fastening screws.
- Slacken the belt by drawing the pump closer to the motor.
- Replace the used belt with a new genuine one.
- Draw it tight moderately by separating the pump from the motor (1daN tension is sufficient) DO NOT OVERTIGHTEN.
- Tighten the 4 pump tightening screws energetically.
D – WATERMAKER MAINTENANCE
FREQUENCY
When it is clogged and at wintering
When it is worn
Every week when used regularly
When it is clogged
Every year
Every year
Each year at wintering
Every year
DESCRIPTION
Filter element 5µ-7''
HP pump oil (0.5 liter)
Storage solution
Cleaner kit A+B
J:\Etude-3d\Aquaset\0-DOSSIER TECHNIQUES\1-sw-plaisance\AQUA-BASE X 2008\09-Manuel utilisateur\AQUABASE XA FRUKES 02-2009-D.doc
NECESSARY SPARE
PARTS
Minimum
1 / year
711014
741045
1 / week
1 / week
1 / year
752038
1 / year
1 / year
752037-EXP10
1 / year
FR/UK/ES Page 27/27