Installation instructions

The installation comes under the exclusive responsibility of specialists.
The installer is held to respect the legislation and the standards used in his home country.
Fitting - installing:
 The piece of furniture or the support in which the hob has to be fitted, as well as the
edges of furniture, the laminate coatings and the glue used to fix them, must be able to
resist temperatures of up to 100 °C.
 The mural rods of edge must be heat-resisting.
 The hobs are classified as "Y" class for heat protection. Ideally the hob should be
installed with plenty of space on either side. There may be a wall at the rear and tall units
or a wall at one side. On the other side, however, no unit or divider must stand
higher than the hob.
 Ensure that there is a distance of 50 mm between the hob and the wall or sides.
 Materials which are often used to make worktops expand on contact with water. To
protect the cut out edge, apply a coat of varnish or special sealant. Particular care must
be given to applying the adhesive joint supplied with the hob to prevent any leakage into
the supporting furniture. This gasket guaranties a correct seal when used in conjunction
with smooth work top surfaces.
 The safety gap between the hob and the cooker hood placed above must respect the
indications of the hood manufacturer. In case of absence of instructions respect a
distance minimum of 760 mm.
 The connection cords should be subjected, after building in, with no mechanical
constraint, such as for example the drawer.

CONNEXION OF THE DIFFERENT ELEMENTS

The installation of this appliance and the connection to the electrical network should be made by
an electrician perfectly aware, and in respect of the normative regulations

Connection of cooking zones

Each connector of the cooking zones, is located by a sticker with the classification from
5 to 8 corresponds to:
 5: Heating zone 1100 W
 7: Heating zone 2300 W
 The fingertouch electronic is located by "C" on the connector
On the technical box, near the female connectors are written: 5-6-7-8-C.
Connect the fingertouch on the "C" of the technical box.
Connect the heating zones with the corresponding number on the technical
box.
To connect easily, begging with the biggest number of the heating zone.
13