SYMBOLS uSED ON LCD
~
AC Measurement
DC Measurement
-
AT
Negative DC Value
Auto range Active
O.L.
Apo
Overload: range Exceeded
Auto power-Off Active
Low Battery
HOLD
Hold Active
V
A
Voltage Measurement
Current in Amps
Ω
resistance in Ohms
Continuity test
k
M
Kilo 10
3
Mega 10
6
ELECtrICAL SpECIfICAtIONS
DC Voltage Measurement
range
resolution
Accuracy
1.0V ~ 1000V
0.001V ~ 1V
± (1.0% + 4 digits)
-1.0V ~ -1000V
0.001V ~ 1V
Overload protection:
1000V
Input Impedance (Nominal): > 10MΩ, < 100pF
AC Voltage Measurement
range
resolution
Accuracy
1.2V ˜ 750V
0.001 ~ 1V
± (1.5% + 3 digits)
Overload protection:
750V RMS
frequency response:
45 to 400 Hz
response:
Averaging
Input Impedance (Nominal): > 10MΩ, < 100pF
Input Impedance (Low Z) > 3kΩ, < 200pF, up to 600V RMS
AC Current Measurement
range
resolution
Accuracy
0.9A ~ 200A
0.1A
± (2.0% + 8 digits)
Overload protection:
• Current:
200A
frequency:
45 to 1kHz
response:
Averaging
resistance Measurement
range
resolution
Accuracy
400Ω ˜ 4MΩ
0.1Ω ˜ 0.001MΩ
± (1.0% + 4 digits)
40MΩ
0.01MΩ
± (2.0% + 4 digits)
Overload protection:
600V RMS
Continuity test
Overload protection
Open Circuit Voltage
threshold (Appx.)
600V RMS
< 0.44V
< 40Ω
Overload protection:
600V RMS
Non Contact Voltage Detector
On Voltage
Appx. 25V AC and above
WArrANtY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
StOrAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISpOSAL / rECYCLE
Do not place equipment and its accessories in the trash. Items
must be properly disposed of in accordance with local regulations.
CuStOMEr SErVICE
KLEIN tOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
customerservice@kleintools.com
www.kleintools.com
139680 Rev. 01/14 B
CL3200
Instruction Manual
ENGLISH
• AutO VOLtAGE
CurrENt
DEtECtION
• BACKLIGHt
• WOrKLIGHt
• LOW Z
• BAr GrApH
• DAtA HOLD
• 3-3/4 DIGIt
3999 COuNt LCD
• AutO rANGE
• NON CONtACt
VOLtAGE tEStEr
750V
1000V
200A

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Klein Tools CL3200

  • Página 1 ± (2.0% + 4 digits) Overload protection: 600V RMS Continuity test CuStOMEr SErVICE Overload protection Open Circuit Voltage threshold (Appx.) KLEIN tOOLS, INC. 600V RMS < 0.44V < 40Ω 450 Bond Street Overload protection: 600V RMS Lincolnshire, IL 60069 1-877-775-5346 Non Contact Voltage Detector customerservice@kleintools.com...
  • Página 2: General Specifications

    GENErAL SpECIfICAtIONS DC Direct Current Dangerous levels Keep hands below line when measuring high current levels. The Klein Tools CL3200 is an auto-ranging general-purpose clamp meter. Auto Power-Off (Apo) DC/AC Voltage or Current Double Insulated Class II It measures AC / DC voltage, AC current, and resistance. It can also test •...
  • Página 3: Garantía

    ± (2,0 % + 4 dígitos) protección contra sobrecarga: 600 V RMS SErVICIO AL CLIENtE prueba de continuidad protección contra Voltaje de umbral (aprox.) KLEIN tOOLS, INC. sobrecarga: circuito abierto 450 Bond Street 600 V RMS < 0,44 V < 40 Ω Lincolnshire, IL 60069, EE. UU.
  • Página 4: Especificaciones Generales

    Corriente directa CD Niveles peligrosos Mantenga las manos por debajo de la línea cuando realice Klein Tools CL3200 es un multímetro de uso general de gancho, de rango mediciones de valores altos de corriente. Voltaje o corriente CD/CA Doble aislamiento Clase II automático.
  • Página 5 600 V RMS AtENDIMENtO AO CLIENtE teste de continuidade proteção contra tensão de circuito Limiar (Aprox.) KLEIN tOOLS, INC. sobrecarga aberto 450 Bond Street 600 V RMS < 0,44 V < 40 Ω Lincolnshire, IL 60069, EUA proteção contra sobrecarga:...
  • Página 6: Detalhes De Recursos

    Níveis de perigo Não tente medir mais do que 1000 V DC ou 750 V AC O Klein Tools CL3200 é um alicate amperímetro com mudança de faixa Mantenha as mãos abaixo da linha ao medir níveis altos de corrente.
  • Página 7 ± (2,0 % + 4 chiffres) protection contre la surcharge : 600 V (valeur efficace) SErVICE À LA CLIENtÈLE test de continuité protection contre la tension à circuit KLEIN tOOLS, INC. Seuil (approx.) surcharge ouvert 450 Bond Street 600 V (valeur efficace) < 0,44 V < 40 Ω...
  • Página 8: Caractéristiques Générales

    CArACtérIStIquES GéNérALES Courant continu c.c. Niveaux dangereux Ne tentez pas de mesurer des valeurs supérieures à 1000 V c.c. Le CL3200 de Klein Tools est un multimètre à pince à échelle automatique. ou 750 V c.a. tension ou courant Double vitrage de Il mesure la tension c.a. / c.c., le courant c.a et la résistance. Il peut aussi Gardez les mains sous la ligne lors de la mesure de courants élevés.