Wiring the UNIRIS II 50
Wire the barrier after removal of the infrared module.
Receiver circuit board connector (RX)
Terminal 1
Terminal 2
Terminal 3
+ Power supply
Terminal 4
- Power supply
Terminal 5
Terminal 6
Terminal 7
Intrusion relay NO
Terminal 8
Intrusion relay COM
Transmitter circuit board connector (TX)
Terminal 1
Terminal 2
Terminal 3
+ Power supply
Terminal 4
- Power supply
Terminal 5
Terminal 6
* Not wired for NH models
Maximum cable length
Wire
∅ ∅ ∅ ∅
wire
section
(mm)
(mm²)
0,6
0,3
0,9
0,6
1,4
1,5
1,8
2.5
Note: When using the same cable to supply power to several components, the indicated distances
are divided by the number of connected components.
When using several wires with the same section in parallel by polarity, the indicated distances
are multiplied by the number of connected wires.
+ Heating *
- Heating *
Tamper
Tamper
+ Heating *
- Heating *
Tamper
Tamper
12V Electronics
T
750
1600
-
-
Switchs 3 and 4 :
Channel selection
Switchs 1 and 2 :
Alignment mode
Green Led 12V
R
T+R
600
300
1300
800
-
1600
-
-
- 14 -
Potentiometer for
setting intrusion
alarm response
Red Led
time
intrusion alarm
1
8
POWER
ALARM
HEATER
TAMPER
1
6
HEATER
TAMPER
POWER
12V Heating
T
R
120
120
280
280
600
600
1000
1000
UNIRIS II 50
T+R
60
140
300
500