Manufacturer:
FAAC S.p.A.
Address:
Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY
Declares that:
Operator model. Night ONE Day Kit, Night ONE Day Radio Kit, Night ONE Day Auto Kit, Night ONE Day Radio Auto kit
• conforms to the essential safety requirements of the other following EEC directives:
2006/95/CE
• conforms to the harmonized norms
- EN 60335-2-103
- EN 61000-3-2, EN 61000-3-3
- EN 55014-1, EN 55014-2
Bologna, 01-02-2011
)
ATTENTION! To ensure the safety of people, it is important
that you read all the following instructions. Incorrect
installation or incorrect use of the product could cause
serious harm to people.
2)
Carefully read the instructions before beginning to install
the product.
3)
Do not leave packing materials (plastic, polystyrene, etc.)
within reach of children as such materials are potential
sources of danger.
4)
Store these instructions for future reference.
5)
This product was designed and built strictly for the use
indicated in this documentation. Any other use, not
expressly indicated here, could compromise the good
condition/operation of the product and/or be a source
of danger.
6)
FAAC declines all liability caused by improper use or
use other than that for which the automated system was
intended.
7)
Do not install the equipment in an explosive atmosphere:
the presence of inflammable gas or fumes is a serious
danger to safety.
8)
FAAC is not responsible for failure to observe Good
Technique in the construction of the closing elements
to be motorised, or for any deformation that may occur
during use.
9)
Before attempting any job on the system, cut out electrical
power.
10)
T h e i n s t a l l a t i o n m u s t b e c a r r i e d o u t
b y q u a l i f i e d t e c h n i c a l p e r s o n n e l ,
observing the current legal regulations
11)
The mains power supply of the automated system must be
fitted with an all-pole switch with contact opening distance
CE DECLARATION OF CONFORMITY
Low Voltage Directive
2004/108/CE
Electromagnetic Compatibility Directive
99/05/CE
RTTE Directive
WARNINGS FOR THE INSTALLER
GENERAL SAFETY OBLIGATIONS
The Managing Director
A. �ar�ella�
A. �ar�ella�
of 3mm or greater. Use of a 6A thermal breaker with all-pole
circuit break is recommended.
12)
Make sure that a differential switch with threshold of 0.03 A
is fitted upstream of the system.
13)
For outdoor use, install the electrical cables inside protection
raceways
14)
Make sure that the earthing system is perfectly constructed,
and connect metal parts of the means of the closure to
it.
15)
Do not, on any account, connect several motors to the
same inverter.
16)
Do not connect two inverters to the same motor.
17)
FAAC declines all liability as concerns safety and efficient
operation of the automated system, if system components
not produced by FAAC are used.
18)
For maintenance, strictly use original parts by FAAC.
19)
Do not in any way modify the components of the
automated system.
20)
The equipment must always be visible when moving.
21)
Do not allow children or adults to stay near the product
while it is operating.
22)
Keep remote controls or other pulse generators away from
children, to prevent the automated system from being
activated involuntarily.
23)
The user must not attempt any kind of repair or direct action
whatever and contact qualified personnel only.
)
Anything not expressly specified in these instructions is
not permitted.