11. Technical data
Mini
Item number 231045
Phase 1
Voltage 110–120 V
Wattage 1.8 kW
Max. amp, load 15 A
Required circuit
breaker size 20 A
Required wire size,
copper 12
AWG
Minimum water flow
0.21
to activate unit
(0.8)
Recommended inlet
temp. range 41–77 °F (5–25 °C)
Nominal water volume 0.026 gal (0.1 l)
Max. working pressure 150 psi (10 bar)
Tested to pressure 300 psi (20 bar)
Weight 3.44 lbs. (1.56 kg)
Height
6
½˝
Depth
Width
7
½˝
Water connections for
Heating system Nichrome bare-wire
Mini
2-1 models are internally restricted to 0.32 gpm (1.2 l/min).
Mini
2-1, 2.5-1, 3-1 ship with a 0.5 gpm (1.9 l/min) pressure compensating fl ow reducer/aerator that must be installed.
Mini
3.5-1, 4-2 ship with a 0.66 gpm (2.5 l/min) pressure compensating fl ow reducer/aerator that must be installed.
- Tankless water heaters are considered a non-continuous load
- Conductors should be sized to maintain a voltage drop of less than 3% under load
- For use with cold water supply only

12. Troubleshooting

E
Safety pressure
cut out
WWW.STIEBEL-ELTRON-USA.COM
2-1
Mini
2.5-1
232098
220816
1
1
110–120 V
110–120 V
2.4 kW
3.0 kW
20 A
25 A
30 A
30 A
10
10
AWG
0.40
0.40
GPM
GPM
(1.5)
(1.5)
l/min
l/min
(165 mm)
(82 mm)
˝
(190 mm)
3
/
˝ O.D. flex connector
8
Symptom
No hot water
despite fully
opened hot
water faucet.
Mini
3-1
Mini
3.5-1
232099
1
110–120 V
3.5 kW
29 A
40 A
10
AWG
AWG
0.40
GPM
GPM
(1.5)
l/min
l/min
Possible cause
No electrical power.
The activation fl ow rate needed to
turn on the heating element has
not been reached.
Safety cut out tripped
MINI
SERIES TANKLESS ELECTRIC WATER HEATERS |
Mini
4-2
Mini
222039
220817
1
1
220–240 V
208 V
220–240 V
3.5 kW
5.7 kW
2.6 kW
14.6 A
12.7 A
23.8 A
20 A
20 A
30 A
12
12
10
AWG
AWG
AWG
0.40
0.77
GPM
GPM
(1.5)
(2.9)
l/min
l/min
Solution
Check the circuit breaker and
check voltage at the wiring block.
Clean fi lter screen.
– turn circuit breakers off
– open Hot Valve to release pres-
sure from the unit
– reset safety pressure cut out
– turn circuit breakers on
6-2
208 V
4.3 kW
20.6 A
30 A
10
AWG
E
9