Mechanical Data; General Features - LEGRAND IME CONTO D4-Pd Manual Del Usuario

Contador de energía 63a, de inserción directa
Ocultar thumbs Ver también para IME CONTO D4-Pd:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

63A energy meter,
direct connection

MECHANICAL DATA

6.2
Screw terminals:
- Depth of the terminals: 12mm
- Lengths of the wire stripping: 11mm
Screw head
:
- Voltage connection terminals (L1, L2, L3): screws with
countersunk head with hexagon socket and Pozidriv No. 2
- Neutral (N) connection terminal: screw/screws with countersunk
head with hexagon socket and Pozidriv No. 2
- Terminal boards in the upper part of the meter (input, impulse
output and bus): screws with countersunk head with hexagon
socket
Recommended torque
:
- Voltage connection terminals (L1, L2, L3): 2.5 Nm
- Neutral (N) connection terminal: 2.5 Nm
- Terminal boards in the upper part of the meter (input, impulse
output and bus): 0.2 N/m
Maximum torque:
- Voltage connection terminals (L1, L2, L3): 3 Nm
- Neutral (N) connection terminal: 3 Nm
- Terminal boards in the upper part of the meter (input, impulse
output and bus): 0.3 Nm
Terminal protection:
- The power terminals are protected with sliding and sealable
terminal front covers which are integrated in the device
Technical data sheet: IDP000189EN_01
Codes: CE4DF30PCL1 – CE4DF3DTCL1 – CE4DF3MTCL1
Model: CONTO D4-Pd

7. GENERAL FEATURES

Marking data:
Indelible marking
3
4
5
6
7
8
9
10
BTICINO SpA
Viale Borri 231
21100 Varese ITALY
imeitaly.com
11
12
14
1. Metrological LED
2. Keypad made up of 2 double-function pushbuttons
(display/configurations)
3. Graphic display
4. Consult the user manual before installation
5. Double insulation
6. Connection on 3-wire three-phase line
7. Connection on 4-wire three-phase line
8. Anti-rotation device (anti-decreasing)
9. Voltage/Current
10. Frequency
11. Product code
12. Datamatrix for product traceability
13. Week and year of manufacture
14. Output connection terminals
15. RAEE Symbol
16. Precision class
17. Temperature of use
18. Outputs
19. Standard
Updated: -
(continues)
RS485
+
kWh-Meter
1Wh/imp
3x230(400)V
0,25-5A (63)A
50-60Hz
CONTO D4
N
L2
L3
L1
Made in Italy
cl.1 Wh - cl.2 varh
-25°C...55°C
CE4DF3DTCL1
T1/T2 (INPUT)
2654280001
19W42
RS485
EN62053-21/23
IEC 61557-12 (PMD2)
Created: 15/03/2019
12
1
2
3 "
15
16
17
18
19
3 | 7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ce4df30pcl1Ce4df3dtcl1Ce4df3mtcl1

Tabla de contenido