Connecting The Rigid Pressure Hose; Disconnecting A Hose Pipe; Connecting Hose To Wall; Operating The Phantom Cleaner - Hayward PHANTOM 6000 Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connecting The Rigid Pressure Hose to Pool
7 . L u b r i c ate the swivel on the 3 ft. Hose Wall End A s s e m b l y (Part T )
in soapy water then snap into one of the Pipe A s s e m b l i e s .
Wall Connector Assembly
N
T
Q
8 . L u b r i c ate the swivel on the Hose Cleaner End A s s e m b l y (Part S)
in soapy water then snap into a different Pipe A s s e m b l y .
Hose Cleaner End Assembly
S
9 . Open Bag #2 and lubricate both ends of the Hose Swivel
Assemblies (Part R) in soapy wat e r. Connect the Pipe
Assemblies by snapping the Hose Swivel Assemblies into each
of the Pipe A s s e m b l i e s .
Hose Swivel Assembly
N
R
Rigid Pressure Hose Assembly
8

Disconnecting a Hose Pipe

If it is necessary to shorten, lengthen or replace a component
of the Rigid Pressure Hose, the Snap Fits can be undone by
twisting the connected Hose Pipes as shown.
Disconnecting Hose Pipes
Connecting Hose to Wall Fitting
1 . With the Booster Pump and Filtration system turned O F F,
look down from the pool deck and hold the Wall Quick
Connect so the hose is to the left and the adjustment knob
is to the right. Insert the Wall Quick Connect into the
Universal Wall Fitting and turn it to the left (counter
clockwise) to lock. The hose should be on the bottom below
the adjustment knob.
2 . Pull the Wall Quick Connect outward to check that the Wa l l
Quick Connect is locked into the Universal Wall Fitting.
3 . To d i s c o n n e c t the hose, first turn the Booster Pump and
F i l t r ation pump O F F then push the Wall Quick Connect
toward the wall, turn it to the right (clockwise) and pull the
Wall Quick Connect out of the Universal Wall Fitting.
Wall Quick Connect
Use Only Genuine Hayward Replacement Parts.
Warning - Risk of Injury
The Filtration and Booster Pumps must be O F F when connecting
or disconnecting cleaner hose.
Caution - Risk of Equipment Damage
The filter pump must alw ays be run to clear air from the system
b e fore turning the Booster Pump O N . Never run the Booster
Pump without the main filter pump O N. Running the Booster
Pump dry will damage the Booster Pump and void the warranty.

Operating the Phantom Cleaner

1 . Be sure all filtration system valves are open and supply i n g
w ater to the Booster Pump.
2 . Be sure valves to and from the Booster Pump and dedicat e d
return line are fully opened.
3 . The Phantom Cleaner and its Booster Pump can only
o p e r ate when the pool's filter pump is operat i n g .
Caution - Risk of Equipment Damage
Failure to open valves fully and/or failure to have the filtrat i o n
system operating will damage the Booster Pump. This damag e
voids the Booster Pump's warranty.

Setting Pressure

I m p o r t a n t : The cleaner will not operate properly if the pressure
is not properly set. Too little pressure will prevent proper
movement and cleaning. Too much pressure will cause poor
cleaning and premature wear of Cleaner parts.
Warning - Risk of Injury
Be careful to hold the Cleaner Connector (Part C) with the Setup
Pressure Gauge (Part U) attached under water and not to be
s p r ayed by the hole in the Setup Pressure Gauge or by the
Sweep Hose. N e v e r point a jet or hose at people or pets.
Clip the Setup Pressure Gauge to the hose near the Wall Quick
C o n n e c t .
1 . Turn the filtration system pump O N then the Booster Pump
O N. Read the pressure on the Setup Pressure Gauge
connected to the Cleaner Connector. Use a fl at blade
screwdriver to adjust the Wall Quick Connect Knob until the
+
pressure reads 25 PSI (
/- 5 PSI).
N o t e : The Wall Quick Connect can be adjusted from " 0 "
( f u l ly closed) to " 5 " ( f u l ly open). Do N OT force the
adjustment knob beyond " 0 " or " 5 " .
2 . If the Wall Connector is on Position " 5 " ( f u l ly open) and the
Use Only Genuine Hayward Replacement Parts.
Operating the Phantom Cleaner
pressure is still below 20 PSI, check for clogged Filter, P u m p
Strainer Basket, Main Drain, Skimmer Basket, e t c . , t o
determine why there is insufficient water pressure at the
d e d i c ated line. If more pressure is still required have an
Authorized Hayward Pool Dealer or Service person check
the Booster Pump, F i l t r ation System and Plumbing to
determine if they are functioning correctly.
3 . Turn the Booster Pump and Filtration Pump O F F.
4 . R e m ove the Setup Pressure Gauge from the Cleaner
C o n n e c t o r. Store the Setup Pressure Gauge with the
O w n e r 's Guide in a safe place.
5 . Attach the Cleaner Connector to Cleaner. The Sweep Hose
should be directly below the Pressure Hose.
6 . Place the cleaner in the pool, turn the Filtration system O N,
then turn the Booster Pump O N.
Setup Pressure Gauge & Wall Connect
K
C
U
Adjusting Pressure at Wall Connector
Connecting Pressure Hose to Cleaner
C
9

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido