GENERAL FEATURES and HOW TO USE
Dualband radio receiver for wireless extension of a traditional alarm system. It needs 12V DC supplied by a control panel and can work with all
Silentron wireless detectors, giving out 4 alarm relays output, a tamper relay output and a supervision relay output.
The device allows a wireless protection on access, doors and windows by means of opening/shock detectors SENSOR TOP and SENSOR
SLIM, infrared barrier LASERBEAM or waterproof SILENT PIR detector, for outdoor protection. R-Evolution 4 can store up to 32 self-
programming detectors divided on 4 alarm zones. Test and alarm of each zone are signalled by 4 red leds.
.
TECHNICAL FEATURES
Power supply: 10-14 V CC
Consumption: 40 mA standard
warnings: 4 zone leds
Input - output : look at logic board picture
K: ON-OFF input from control panel - programmableby dip-switch 3
A-B-C-D: free NC alarm output (0,1A max)
TAMPER: free NC anti-tamper alarm output (0,1A max) - look at note 1
RF: free NC antiscanner & supervision alarm output (0,1A max) - look at note 2
Radio receiver: superherodyne receiver - sensitivity -105dbm - frequency about 400 MHz and 850 MHz - frequency and features according to
the Rules - approx. indication for security reasons
Programmable wireless detectors: 1 to 32 self -programming detectors on 4 alarm zones
Stock and operating temperature 0°C +55°C
Protection degree: IP 41
NOTES:
1) alarm is given either when the housing of R-Evolution, or the housing of a programmed radio detector is opened.
2) alarm is given from failed supervision signals (dip switch 3 ON) even from a single detector, and latest after 8 hours. Likewise there will be
alarm when both the receivers (dip switch 4 ON) are saturated at the same time for over 1min.
3) connection of terminal K will enable led memorization of occurred alarm and its reset each time the control is armed. Program the input
polarity with dip switch 2. When terminal K is not connected the device will work, but without led visualization of the alarm memory.
PROGRAMMING OF WIRELESS DETECTORS
For obtaining total deletion of possibile detectors previously programmed press S1 while supplying power.
1)
Supply R-Evolution and press P1 pushbutton: in this mode we reset all radio codes stored in the device: led A will blink.
2)
Press S2 to shift the zone A Ù B Ù C Ù D. Select the proper zone: the led will blink.
3)
Insert battery into the first wireless detector: the led will light 5 seconds and buzzer will sound, confirming the right programming.
4)
Insert battery into the second wireless detector and so on. When necessary, change the zone.
.
Reset of programmed detectors:
press S1 just one second to obtain the "programming status" - select the zone to reset by pressing S2 and press S1 just 10 seconds. When led
switches off for 5 sec. and buzzer sounds, all detectors on the zone are cancelled.
To add detectors
press S1 just one second to obtain the "programming status" , select the zone and insert battery into the detector. For terminating
programming:
press keys S1 and S2 at the same time.

RELAY OUTPUT:

all free contacts are NC and temporary open in case of alarm. The 5418 Sensor Silenya and 5015-16-17 Sensor Top can be installed with
"opening and closing door" function. In this case, if the door remains open, the relay output will be open all the time.
Low battery of wireless detectors:
a warning radio signal starts when the battery is low and R-Evolution sounds 5 BEEP and the led of the zone blinks. Moreover, the buzzer
sounds at each arming-disarming of the system. Please change the battery a.s.a.p. in order to avoid a supervision alarm.
Leds indications:
temporary lighting = alarm
permanent lighting = alarm memory
permanent blinking = low battery of a wireless detector
SILENTRON - ITALIA
Dimensions: 64x125x45h mm
- TEST condition when dip-switch 1 is ON
Weight: 90 g
COPYRIGHT SILENTRON