Installation; Installation Considerations - Thermador VCIN60RP Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Installation Considerations

The custom insert unit is designed for installation inside a
custom-built hood assembly. It is for ducting to the outside.
It cannot be used in conjunction with a recirculation unit.
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual.
7/ 16
7
7
7
"
(188)
(188)
(188)
11/ 16
12
12
12
"
(326)
(326)
(326)
* 30" (762) min.
* 30" (762) min.
* 30" (762) min.
40" (1,016) max.
40" (1,016) max.
40" (1,016) max.
to Cooking Surface
to Cooking Surface
to Cooking Surface
* Follow cooking appliance manufacturer's recommendations
NOTICE:
The hood could incur some damage from heat if a
THERMADOR PROFESSIONAL
is operated with multiple burners at high settings under a
hood that is installed at minimum clearances.
Installation Instructions
Electrical Zone
* Hood width should be
no less than the width
of the cooking surface.
Cooking
Surface
inches (millimeters)
Figure 2: Typical Hood Installation
®
series range or rangetop
Hood Width
The hood width should be no less than the width of the
cooking surface. For proper performance, the housing must
cover the entire cooking surface.
For proper performance, the hood must be centered
horizontally above the cooking surface.
Distance From Cooking Surface
The installation height ranges from a minimum height of
30'' (762 mm) to a maximum height of 40'' (1,016 mm);
however, it is necessary to follow the cooking appliance
manufacturer's installation instructions for proper hood
height.
Unit Weight
When calculating the load for the housing support system,
be sure to consider the weight of the ventilation unit.
Hood, Filters, Grease Trays, and Trims
Integral Blower Model VTN1090
IMPORTANT:
The supplied weights address only the ventilation unit and
blower. Installer must account for weight of any materials
of construction when calculating the total dead weight
load of installation, including but not limited to: wall, tile,
mortar, plaster, brick, finishes, partitions, and other
similarly incorporated architectural and structural items. It
is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
Blower Motors
Integral, in-line and remote blowers are available through
your authorized THERMADOR
information, visit the Find a Dealer section of our website at
www.thermador.com.
The blower will vary in size and is dictated by the cooking
surface, the volume of air that needs to be moved and the
length of the duct run. Refer to "Blower Motor Installation"
on page 13 for detailed blower motor information.
Weight
81 lb (37 kg)
23 lb (11 kg)
Table 1: Unit Weight with Blower
®
dealer. For local dealer
English | 7 |

Publicidad

Tabla de contenido
loading

Tabla de contenido