Chapter 2. How to Configure and Program the Control
Figure 33: Water Quantity screen
12. Enter the quantity of water that is in the calibration container, then touch the checkmark to
confirm the value and return to the calibration screen.
13. Touch the Save Data button on the Flow Meter Calibration screen
(Figure
32).
14. Connect the water inlet hose to the water inlet on the machine cylinder.
— End of BICLWC02 —
BICLWP02 (Published) Book specs- Dates: 20170301 / 20170301 / 20170301 Lang: ENG01 Applic: CLW
2.4. Using Programmable Outputs
®
™
The Milnor
MilTouch-EX
controller can operate up to 20 optional output relays. You assign
these relays to operate in specific formulas and steps. You also assign the event that will trigger
the output, the delay before the output operates, and the length of time that the output will
operate.
Figure 34
shows the button on the Formula Modification display that opens the
Programmable Outputs display.
Figure 34: Access to the Programmable Outputs Display
1. On the Programmable Outputs screen
(Figure
35), touch the Add Output button to begin.
PELLERIN MILNOR CORPORATION
40