Federal Signal Global Serie Instrucciones De Instalación Y Mantenimiento página 20

Ocultar thumbs Ver también para Global Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation and Maintenance Instructions
Tools needed:
• 1.5 mm A/F hexagon key
• 2 mm blade-tip screwdriver
• No. 1 Phillips screwdriver
To select a pattern:
1.
Disconnect power to the beacon.
2.
Unscrew the M3 set screw on the side of the housing one full turn.
3.
Remove the lens cover from the housing by turning the cover
counter-clockwise. Three 120-degree spaced reliefs are provided
for a spanner wrench if needed. If the cover assembly will not
unscrew, back out the set screw a few additional turns
4.
Loosen the captive Phillips screw retaining the printed circuit
board (PCB), and slide out the PCB until DIP switch SW1
is accessible.
5.
Select a flash pattern by setting the DIP switches on SW1. Steady
On is the default.
6.
Insert the PCB assembly into the enclosure and fully tighten the
captive screw.
7.
Place the cover on the housing and tighten it by turning it clockwise.
To ensure O-ring compression, the cover must be fully seated
against the housing when the threads are tightened.
8.
Turn the M3 set screw against the housing until the screw
contacts the housing.
9.
Reconnect power to the beacon.
10. Test the beacon by applying power and verifying the pattern.