Maintaining the Beacon
EXPLOSION HAZARD: To prevent ignition of hazardous atmosphere,
disconnect the beacon from the supply circuit before opening it.
Do not open the beacon in the presence of explosive gases in the
atmosphere. Failure to follow this warning may result in serious
injury or death.
During the working life of the beacon, it should require little or no
maintenance. The non-metallic housing will resist attack by most
acids, alkalis, and chemicals and is as resistant to concentrated acids
and alkalis as most metal products. However, if abnormal or unusual
environment conditions occur due to plant damage or accident, etc.,
visual inspection of the beacon is recommended.
Cleaning the Enclosure
The enclosure should be cleaned periodically with a damp cloth to
maintain maximum light output. The polycarbonate colored LED
lens should be regularly inspected for cracks. If it is damaged, it
must be
replaced.
for any applicable Specific Conditions of Use.
Replacing the LED Array
EXPLOSION HAZARD: To maintain the flameproof integrity
of the enclosure, DO NOT damage the lens cover, or threads
while disassembling or reassembling the beacon.
LIGHT HAZARD: To be an effective warning device, the beacon
produces bright light that can be hazardous to your eyesight
when viewed at close range. Do not stare directly into the
beacon at close range or permanent damage to your eyesight
may occur.
Federal Signal LED array part No. K859500823-*
Model G-LED Global Series LED Beacon
Installation and Maintenance Instructions
Refer to the "Certification" section on page 6
23