HOSE AND REGULATOR:
Your fryer is equipped with a Type 1 connection device with
the following features:
1. The system will not allow gas flow from the cylinder until
a positive connection to the valve has been made.
Note:
The cylinder valve must be turned off before any
connection is made or removed.
2. A thermal device that will shut off the gas flow if the device
is subject to temperatures above 240°F to 300°F (115°C to
150°C). If this should happen, remove the entire regulator
assembly and dispose of properly. A replacement regulator
assembly can be purchased by contacting Brinkmann at
1-800-527-0717. The cause of the excessive heat should
be determined and corrected before using your fryer again.
3. A flow limiting device, when activated, restricts the flow
of gas to 10 cubic feet per hour.
•
Never use your fryer without leak testing all gas connections and hoses. See the section on
"Leak Testing" in this manual for proper procedures.
The pressure regulator and hose assembly supplied with your gas fryer is designed to work with an
LP gas supply cylinder.
•
DO NOT attempt to connect it to any other fuel supply source such as a natural gas line.
•
DO NOT use any other pressure regulator/hose assembly other than the one supplied with your fryer.
•
DO NOT attempt to adjust or repair the regulator. A replacement regulator can be supplied by
contacting Brinkmann. The regulator is designed to operate at a maximum output pressure of
5 psi ( pounds/square inch).
During assembly and/or replacement of the gas cylinder, keep the gas supply hose free of kinks and/or
damage.
Visually inspect the hose assembly prior to each use for evidence of damage, excess wear, or
deterioration. If found, replace the assembly before using your fryer. Only the Brinkmann supplied
replacement should be used.
WARNING
WARNING
6